overview

This PC application software, ”BT4560 Application Software”, transfers measurement data from BT4560 Impedance Meter to PC and displays measurement result visually and makes available measurement parameters setting.

Operating Environment

OS:Windows Vista(SP2 or later)/ Windows 7 / Windows 8 / Windows 8.1 / Windows 10 (32-bit or 64-bit) Software Environment : Microsoft .NET Framework 4.0 or 4.5 CPU:CPU clocked at 1GHz or greater Memory:512MB memory or more Display :1024x800 dots or more Hard Disk:550MB hard disk space or more Communication interface :USB2.0(virtual COM port)

* Microsoft .NET Framework 4.0 or 4.5 is required for this software.

Specifications

・Display of measurement results in graph and list form. ・Setting of measurement parameters ・Saving recorded measurement data as CSV text file ・Send record data to Excel ・Send arbitrary command and receive response of query ・Calculate measurement accuracy

Installation procedure

1.Click [Download] and download the file. 2.Decompress the downloaded file. 3.Double click the [Appli]-[setup.exe] file and follow the instructions appearing on the screen. 4.After installation has completed, the decompressed file can be deleted.

Version Upgrade History

Rev4 V1.04 (July 2015) Newest version * Improved the suspension process when clicking the stop button in the Cole-Cole Plot analysis. * Improved the way to set the time interval of repeat measurement in the Cole-Cole Plot analysis. The interval setting in seconds, minutes or hours is now available. * Improved the display location of the X-Axis in the Cole-Cole Plot analysis. * Improved the save button’s caption. * Improved the Analyzer window to be resized by the mouse operation. * Add the feature to set the delay time before the start of measurements. Rev3 V1.03 (April 2015) * Fixed a bug that the application does not detect com ports in a particular environment. * Fixed a bug that [Analyze]-[Set] dialog shows an error message on the OS other than Japanese OS and English OS. * Fixed other minor bugs. Rev2 V1.02 (December 2014) *Fixed a bug that the minimum resolution is not applied to sweep frequencies in the particular frequency range. Rev1 V1.01 (November 2014) * First Release