fbpx

BATTERY HiTESTER BT3561A

Fully automated production line testing of small cells for power motors or small packs of up to 60 V

Shop Now

CONTACT US
SKU: BT3561A Category: ,

Description

Key Features

• Simultaneous measurement of internal resistance and open circuit voltage.
• Fully automated production line testing of small cells for power motors or small packs of up to 60 V.
• Resistance measurement ranges: 30 mΩ/300 mΩ/3 Ω/30 Ω/300 Ω/3 kΩ
• Voltage measurement ranges: 6 V/60 V
• Equipped with LAN

Model No. (Order Code)

BT3561A

Note: Measurement leads are not included. Purchase the appropriate lead option for your application separately. The male (system side) of the EXT I/O connector is also available. Please contact your authorized Hioki distributor or reseller

LAN
CE
RS232C
3 year

 

Measuring battery performance and safety using internal resistance (AC-IR) and open-circuit voltage (OCV)

Inspect the quality of completed cells, modules, and packs on production lines. Measure internal resistance (AC-IR) and open-circuit voltage (OCV) to check battery quality. Cells produced at the cell production factory are shipped to the module production factory after undergoing a shipping inspection. Since factors such as vibrations during shipment and even the passage of time can cause defects, batteries undergo an acceptance inspection before being assembled into modules and packs. BT3561A Small cells for power motors, Small packs of up to 60 V Voltage measurement ranges: 6 V/60 V Resistance measurement ranges: 30 mΩ/300 mΩ/3 Ω/30 Ω/300 Ω/3 kΩ BT3562A Large cells for xEVs, Mid-sized packs of up to 100 V Voltage measurement ranges: 6 V/60 V/100 V Resistance measurement ranges: 3 mΩ/30 mΩ/300 mΩ/3 Ω/30 Ω/300 Ω/3 kΩ BT3563A Large packs for xEVs, Large packs of up to 300 V Voltage measurement ranges: 6 V/60 V/300 V Resistance measurement ranges: 3 mΩ/30 mΩ/300 mΩ/3 Ω/30 Ω/300 Ω/3 kΩ

 

Reducing test system development cost and management man-hours

The new BT356xA has dramatically improved tolerances for line resistance compared to previous models. This improvement makes it easy to build test systems with large numbers of channels using relays. Additionally, a longer maintenance cycle for systems in use means fewer maintenance man-hours. Finally, its capability to handle thinner cables than with previous models* makes it easier to route cables. *AWG 29 (0.064 mm2) wire equivalent to 2.2 Ω over an 8 m round trip can be used with the 3 mΩ or 30 mΩ range.

 

Improve Productivity by Increasing the Number of Inspection Channels

You can use the Switch Mainframe SW1001/SW1002 to increase the number of measurement channels. Additionally, you can perform scan measurement by controlling two instruments at once, for example a BT356xA series instrument and a DM7276, or a BT4560 and a DM7276.

 

Preventing instrument malfunctions caused by static electricity

Batteries can become charged on production lines, for example, when being transported on a conveyor belt. When probes are placed in contact with such batteries, the resulting application of static electricity can then damage the instrument. The BT356xA series is designed to withstand contact with ±30 kV of static electricity*, preventing static-caused malfunctions and reducing testing line downtime. * ±30 kV IEC 61000-4-2 contact discharge

 

LAN interface as standard

The BT356xA series is equipped with a LAN interface as standard equipment, making it easy for the instrument to interoperate with a PLC*-based control system. The ability to use readily accessible LAN cables helps lower costs during system development and maintenance. Furthermore, a design with strong noise and static electricity resistance helps avoid system problems. *Programmable Logic Controller, a device that automatically controls one or more machines

 

The De Facto Standard of Battery Testers

The HIOKI BT356xA series These highly advanced battery testers are best suited for shipping and acceptance inspections of cells and battery packs. They simultaneously measure internal resistance and the battery’s open-circuit voltage (OCV). Since the AC-IR measurement method is used, the measurement time is shortened. In addition, highly repeatable results are attained with this method. These testers have a highly accurate 3 mΩ range, allowing for a resistance measurement of battery tab welding and bus bars. All of this combines for the best choice in battery testers. High input voltage applications The input high voltage (1,000 V) model, BT3564, can measure the total resistance of the battery whole pack at once. *Watch with the video subtitles on, to see detailed descriptions.

 

Basic specifications (Accuracy guaranteed for 1 year, Accuracy guarantee period after adjustment made by Hioki: 1 year)

Resistance measurement ranges30 mΩ(Max. display: 31.000 mΩ, resolution: 1 μΩ, measurement current: 100 mA)
300 mΩ(Max. display: 310.00 mΩ, resolution: 10 μΩ, measurement current: 10 mA)
3 Ω(Max. display: 3.1000 Ω, resolution: 100 μΩ, measurement current: 1 mA)
30 Ω(Max. display: 31.000 Ω, resolution: 1 mΩ, measurement current: 100 μA)
300 Ω(Max. display: 310.00 Ω, resolution: 10 mΩ, measurement current: 10 μA)
3 kΩ(Max. display: 3.1000 kΩ, resolution: 100 mΩ, measurement current: 10 μA)

Basic accuracy: ±0.5% rdg ±5 dgt(30 mΩ range or more)
Measurement frequency: 1 kHz ±0.2 Hz
Measurement method: AC four-terminal method

Voltage measurement ranges6 V(Max. display: 6.00000 V, resolution: 10 μV)
60 V(Max. display: 60.0000 V, resolution: 100 μV)

Basic accuracy: ±0.01% rdg. ±3 dgt.

Response time10 ms
Sampling periodΩ or V (60 Hz): 4 ms (EX.FAST), 12 ms (FAST), 35 ms (MEDIUM), 150 ms (SLOW)
ΩV (60 Hz): 8 ms (EX.FAST), 24 ms (FAST), 70 ms (MEDIUM), 253 ms (SLOW)

Ω or V (50 Hz): 4 ms (EX.FAST), 12 ms (FAST), 42 ms (MEDIUM), 157 ms (SLOW)
ΩV (50 Hz): 8 ms (EX.FAST), 24 ms (FAST), 84 ms (MEDIUM), 259 ms (SLOW)

FunctionsContact check, Zero adjustment (±1000 counts), Pulse measurement, Comparator (Hi/ IN/ Lo), Statistical calculations (Max. 30,000), Delay, Average, Panel saving/loading, Memory storage, LabVIEW® driver
InterfacesLAN (TCP/IP, 10BASE-T/100BASE-TX)
RS-232C (Max. 38.4 kbps, Available as printer I/F)
EXT I/O (37-pin Handler interface)
Analog output (DC 0 V to 3.1 V)
Power supply100 to 240 V AC, 50 Hz/60 Hz, 35 VA max.
Dimensions and mass215 mm (8.46 in) W × 80 mm (3.15 in) H × 295 mm (11.61 in) D, 2.4 kg (84.7 oz)

Catalogs

Catalog: BATTERY HiTESTER Series

Catalog Preview: BATTERY HiTESTER BT3561A, BT3562A, BT3563A

BATTERY HiTESTER BT3561A, BT3562A, BT3563A

Renewal of HIOKI's world-leading battery tester

Manuals

BATTERY HiTESTER BT3561A,BT3562,BT3562-01,BT3562A,BT3563,BT3563-01,BT3563A [7MB]

Outline Drawings

BATTERY HiTESTER BT3562A [78KB]

Declaration of Conformity

Declaration of Conformity: BATTERY HiTESTER BT3561A,BT3562A,BT3563A

User Guides

Electrical Measurements of Lithium-Ion Batteries

Lead-acid Battery Handbook

Drivers, Firmware

LabVIEW driver for BATTERY HiTESTER 3561,BT3562,BT3563,BT3564,BT3561A,BT3562A, BT3563A

Freeware - Version 1.01

Options

Compatible products

Last update: June 15, 2018

 

SWITCH MAINFRAME SW1001

• Pair with a measuring instrument for quick, multi-channel battery testing • Max 60V DC input • Max. 18 (4-terminal pair) to 66 (2-wire) channels

SWITCH MAINFRAME SW1002

• Pair with a measuring instrument for quick, multi-channel battery testing • Max 60V DC input • Max. 72 (4-terminal pair) to 264 (2-wire) channels

Measurement Leads A (for measuring high voltage batteries)

 

PIN TYPE LEAD L2100

A:300 mm (11.81 in), B:172 mm (6.77 in), L:1400 mm (4.59 ft), for high voltage battery measurements, 1000 V DC max.

TIP PIN 9772-90

To replace the tip on the Pin type lead 9772, L2100/L2110, (one piece)

PIN TYPE LEAD L2110

A: 750 mm (29.53 in.), B: 215 mm (8.46 in.), L: 1880 mm (6.17 ft.), for high voltage battery measurements, 1000 V DC max.

Measurement Leads C

 

LARGE CLIP TYPE LEAD 9467

A:300 mm (11.81 in), B:116 mm (4.57 in), L:1360 mm (4.46 ft), 50V DC

Measurement Leads C (for measuring batteries up to 60 V)

 

CLIP TYPE LEAD L2107

A: 130 mm (5.12 in), B:84 mm (3.31 in), L:1.1 m (3.61 ft), 60 V DC

FOUR TERMINAL LEAD 9453

A:280 mm (11.02 in), B:118 mm (4.65 in), L:1360 mm (4.46 ft), 60V DC

Options

 

0 ADJ BOARD Z5038

For L2110, L2020, 9465-10, 9772

PC communication

*The 9151-02 is only for the RM3545-01

 

RS-232C CABLE 9637

For the PC, 9 pin - 9 pin, cross, 1.8 m (5.91 ft) length