Product Details
LR8400 Data Logger --HTI
30 to 60 Channel Data Logger







Download Brochure
Download Brochure
Category:Memory Recorders/Loggers

Description:
LR8400-20 (with built-in VOLTAGE/TEMP UNIT × 2)

Built-in units are equivalent to the VOLTAGE/TEMP UNIT LR8500 (15 ch) × 2

Caution: Built-in units cannot be removed or changed


LR8401-20 (with built-in UNIVERSAL UNIT × 2)

Built-in units are equivalent to the UNIVERSAL UNIT LR8501 (15 ch) × 2

Caution: Built-in units cannot be removed or changed


LR8402-20 (with built-in UNIVERSAL UNIT × 1, VOLTAGE/TEMP UNIT × 1)

Built-in units are equivalent to the UNIVERSAL UNIT LR8501 (15 ch) × 1, and VOLTAGE/TEMP UNIT LR8500 (15 ch) × 1

Caution: Built-in units cannot be removed or changed


Portable Data Logger with 30 Standard Channels, Expandible to 60 Channels


•Compact size despite 30-channel standard capabilities

•Expand up to 30 additional channels

•Protected against unexpected power outages

•Write data to USB memory stick or CF card in real-time

•Built in with USB 2.0 or 100 BASE-TX LAN interfaces

•5.7" TFT color display

Specifications:
Analog input UNIVERSAL UNIT LR8501

Actual functionality will depend on combination of units installed [No. of channels] 15 analog channels; isolated scanning method input (4 terminals: push-button type)

[Voltage] 10 mV to 100 V, 1-5 V f.s. 10 ranges, Max. resolution: 500 nV

[Temperature: Thermocouples] -200°C to 2000°C (depends on sensor), 3 ranges (K, J, E, T, N, R, S, B, W), Max. resolution 0.01°C

[Temperature: Pt 100, JPt 100 sensor] -200°C to 800°C, 3 ranges, Max. resolution 0.01°C

[Resistance] 10 Ω to 200 Ω f.s. 4 ranges, Max. resolution 0.5 mΩ

[Humidity] 100 % rh f.s. 5.0 to 95.0 % rh (when using Z2000), resolution 0.1 % rh

[Max. rated voltage between isolated input channels] 300 V DC

[Max. allowable input] ±100 V DC

[Max. rated voltage from isolated terminals to ground] 300 V AC, DC

Caution: Not isolated from each other and common GND at platinum temperature sensor or resistance measurement input

Analog input VOLTAGE/TEMP UNIT LR8500

Actual functionality will depend on combination of units installed [No. of channels] 15 analog channels; isolated scanning method input (2 terminals: M3 screw type)

[Voltage] 10 mV to 100 V, 1-5 V f.s. 10 ranges, Max. resolution: 500 nV

[Temperature: Thermocouples] -200°C to 2000°C (depends on sensor), 3 ranges (K, J, E, T, N, R, S, B, W), Max. resolution 0.01°C

[Temperature: Pt 100, JPt 100 sensor] [Resistance] not available

[Humidity] 100 % rh f.s. 5.0 to 95.0 % rh (when using Z2000), resolution 0.1 % rh

[Max. rated voltage between isolated input channels] 250 V DC

[Max. allowable input] ±100 V DC

[Max. rated voltage from isolated terminals to ground] 300 V AC, DC

Caution: Max. voltage from terminals to ground without damage

Pulse, Digital input [No. of channels] 8 channels, pulse / digital selectable for each channel, M3 screw terminal, not isolated, common ground

[Pulse totalization] 0 to 1000 M pulse, 1 range (No-voltage 'a' contact; normally open, open collector or voltage input), Max. resolution 1 pulse

[Pulse revolutions] 0 to 5000 /n (r/s) f.s. 1 range (same as Pulse totalization input signal condition), resolution 1/n (r/s) Note: "n" is the number of sensor output pulses per revolution, 1 to 1000

[Digital input] Record logical "1" or "0" at each sampling

[Max. rated voltage between input channels] Not isolated

[Max. allowable input] 0 to 50 V

Recording intervals 10 ms to 50 ms, 100 ms to 1 hour, 19 selections (All input channels are scanned at high speed during every recording interval)

Note: limited by using channels at 10 ms to 50 ms interval

Digital filter Select from OFF/ 50 Hz/ 60 Hz (the cut-off frequency is automatically set)

Data storage Internal memory: 8 M-words, Data storage media: CF card or USB memory

(Only data recorded to a genuine HIOKI CF card is guaranteed)

LAN interface 100BASE-TX, Functions: Data acquisition using bundled software or PC commands, FTP server, FTP client, HTTP server function, or E-mail system

Note: LAN communication support planned from software Ver. 1.20

USB interface USB 2.0 High-speed capable, series mini-B receptacle

Functions: Data acquisition using bundled software or PC commands, Transfer data from the CF card to a PC via USB drive mode

Note: Data transfer not possible from USB memory sticks

Display device 5.7 inch TFT color liquid crystal display (640 × 480 pixel)

Other functions Save waveform data in real time to the CF card or USB memory stick, Numerical value calculations, Waveform calculations, and others

AC Power Using the AC ADAPTER 9418-15 (100 to 240 V AC, 50/60 Hz), 7 VA

DC Power Using the BATTERY PACK Z1000 (optional accessory), Continuous use 5 hr, External power: 10 to 28 V DC (Please contact your HIOKI distributor for connection cord)

Dimensions & Mass 272 mm (10.71 in) W × 182.4 mm (7.18 in) H × 66.5 mm (2.62 in) D, 1.8 kg (63.5 oz), (LR8400-20 main unit, excluding the Battery Pack 370 g/ 13.1 oz)

Accessories Detailed operating manual ×1, Measurement guide ×1, AC ADAPTER 9418-15 ×1, USB cable ×1, CD-R (data collection software "Logger Utility") ×1