Description

The Waveform Generator Unit MR8790 is a plug-and-play module for Hioki Memory HiCorders that offers high-precision DC voltage output for generating signals that simulate voltage fluctuations at very low levels.

Key Features
• Output sine waves (20 kHz max.) and DC voltage signals up to 4 channels per unit
• Output signals up ±10V or 5mA
• For use with Hioki Memory Hicorder series (cannot use with 8847 or MR8847)
• Isolated between unit and output, and between all channels

Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)

Output terminal Number of channels: 4, SMB terminal (Output impedance: 1 Ω or less)
Max. rated voltage to ground: 33 V rms AC or 70 V DC
Output voltage range -10 V to 10 V (Amplitude setting range: 0 V to 20 V p-p, Setting resolution: 1 mV)
Max. output current 5 mA
Output function DC, Sine wave (Output frequency range: 0 Hz to 20 kHz)
Accuracy Amplitude accuracy: ±0.25% of setting ±2 mV p-p (1 Hz to 10 kHz)
Offset accuracy: ±3 mV
DC output accuracy: ±0.6 mV
Other Self-test function (Voltage, Current)
Dimensions and mass 06 mm (4.17 in) W × 19.8 mm (0.78 in) H × 196.5 mm (7.74 in) D, 230 g (8.1 oz)
Accessories None

Catalogs

Waveform Generator System U8793,MR8847A

Technical Notes

Arbitrary Waveform Generator Unit U8793, Waveform Generator Unit MR8790, and Pulse Generator Unit MR8791

Options

Output cables

* Please contact your local HIOKI distributor for connectors that support Model MR8791.

 

CONNECTION CABLE L9795-01

SMB to alligator clip, 1.5 m (4.92 ft) length

CONNECTION CABLE L9795-02

SMB to BNC terminal, 1.5 m (4.92 ft) length

Use with these Products

*Cannot use with 8847 or MR8847

 

MEMORY HiCORDER MR8847A

• Max. 16ch Analog + 16ch Logic • Max. 10ch Analog + 64ch Logic • 20M-Sampling/s • 32M to 256M-Word Memory (2ch) • Waveform judgment function • 12-bit/16-bit A/D resolution • USB, HD, CF-card

MEMORY HiCORDER MR8827

• Max. 32ch Analog + 32ch Logic • Max. 28ch Analog + 64ch Logic • 20M-Sampling/s • 16M to 128M-Word Memory (4ch) • 12-bit/16-bit/24-bit A/D resolution • USB, SSD, CF-card

MEMORY HiCORDER MR8740, MR8741

• Max. 54ch/16ch Analog + 16ch Logic • 20M-Sampling/s • 12-bit/16-bit A/D resolution

There are no drivers, firmware or software available for this product.