RESISTANCE HiTESTER RM3543

10 mΩ to 1000 Ω DC Resistance Meters with 0.01μΩ Resolution and Strong Noise Immunity for Integration into Automated Production Lines

SKU: RM3543 Category:

Model No. (Order Code)

RM3543
RM3543-01 with GP-IB interface

Note: Test fixtures are not supplied with the unit. Select an optional test fixture when ordering.

CE
GPIB
RS232C

 

Description

Hioki DC resistance meters measure a broad range of resistance values at a high level of precision. The RM3543 is designed to be integrated into current sensing resistor taping machines, deliver high-accuracy measurement of super-low-resistance levels, and are advanced enough to measure 0.1 mΩ shunts with room to spare.

 

 

Key Features

• Advanced enough to measure 0.1 mΩ shunts with room to spare at ±0.16% accuracy & 0.01μΩ resolution performance
• Superb repeatable measurement accuracy
• Advanced contact-check, comparator, and data export functions
• Intuitive user interface and strong noise immunity are ideal for automated systems

 

 

A resistance tester that can measure super-low resistance values and shunt resistors

The Resistance Meter RM3543 can measure low shunt resistance values and other DC resistance values at a high accuracy of ±0.16% for 0.1 mΩ and at the high resolution* of 0.01 μΩ.
*In the 10 mΩ range, at SLOW measurement speed, and with 16 averaging iterations.

 

 

Reduce the effects of thermoelectromotive force with the offset voltage correction

Thermoelectromotive force refers to the potential difference that occurs at junctions between different metals (see figure). Specifically, the phenomenon occurs where measurement probes and measurement targets come into contact, and at connections between measuring instruments and measurement leads. The magnitude of this thermoelectromotive force varies with the temperature of the measurement environment, increasing as the temperature difference grows. The RM3543 includes an offset voltage correction function that applies the measurement current in both the positive and negative directions and then uses the resulting detected voltages to eliminate the effects of thermoelectromotive force.

 

 

Use the scaling function to correct measurements as if the target component were mounted

The RM3543’s scaling function can correct for the difference in resistance values that are obtained when testing a given component alone and when it is mounted on a circuit board (due to the factors such as the effects of probing position). This feature is useful when testing low-resistance current-sensing resistors such as shunts.

 

 

Ensure reliable contact quickly with the contact improvement function

The RM3543 improves contact with measurement specimens by eliminating oxide films and dirt between the probes and specimens. By addressing faulty contact, the instrument facilitates stable measurement and reduces the contact error rate, boosting productivity.

 

 

Using probe short detection functionality to ensure the reliability of 4-terminal measurement

The presence of any foreign material between the POT and CUR measurement probes can interfere with reliable 4-terminal connections. The RM3543 checks for probe short-circuits by measuring the resistance value between POT and CUR while measurement is not being performed.

 

 

Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)

Measurement method Four-terminal, constant-current DC
Resistance range 10 mΩ (Max. 12.00000 mΩ, 0.01 μΩ resolution) to 1000 Ω range (Max. 1200.000 Ω, 1 mΩ resolution), 7 steps
Display Monochrome graphic LCD 240 × 64 dot, white LED backlight
Measurement accuracy [at 10 mΩ range, with SLOW mode, average 16 times settings]
±0.060 % rdg. ±0.001 % f.s.
Testing current [at 10 mΩ range] 1 A DC to [at 1000 Ω range] 1 mA DC
Open-terminal voltage 20 V DC max. Note: Voltage when not measuring is 20 mV or less, with current mode set at PULSE and Contact Improver Setting set at OFF/PULSE (measured with a voltmeter having 10 MΩ)
Sampling rate FAST, MEDIUM, SLOW, 3 settings
Integration time [at 10 mΩ range, default value] FAST 2.0 ms, MED 5.0 ms, SLOW 1 PLC,
Setting range: 0.1 ms to 100.0 ms, or 1 to 5 PLC at 50 Hz, 1 to 6 PLC at 60 Hz Note: PLC = one power line cycle (mains wave-form period)
Other functions Comparator (compare setting value with measurement value), Delay, OVC (offset voltage compensation), Average, Measurement fault detection, Probe short-circuit detection, Improve contact, Current mode setting (A pulse application function that applies current only during measurement), Auto-memory, Statistical calculations, Settings monitor (when using two instruments, a difference in settings causes warning notification), Retry, Trigger function. etc,.
Interfaces External I/O, RS-232C, Printer, GP-IB (Model RM3543-01)
External I/O Trigger, Hold input, Comparator output, Settings monitor terminal, Service power output +5V, +12V, etc.
Power supply 100 to 240 V AC, 50/60 Hz, 40 VA max.
Dimensions and mass 260 mm (10.24 in) W × 88 mm (3.46 in) H × 300 mm (11.81 in) D, 3.0 kg (105.8 oz)
Accessories Power cord ×1, EXT. I/O male connector ×1, Instruction manual ×1, Operation guide ×1

Catalogs

RESISTANCE HiTESTER RM3543, RM3543-01

User Guides

Technical Note: Shunt Resistor Measurement Vol.5

Technical Note: Wide or Thick Resistor Measurement Vol.4

Technical Note: Introduction to Resistance Measurement Vol.1

Technical Note: Resistance Measurement of Busbar Welds Vol.3

Declaration of Conformity

RESISTANCE HiTESTER RM3543,RM3543-01 [121KB]

Options

PC communication

 

GP-IB CONNECTOR CABLE 9151-02

2 m (6.56 ft) length

RS-232C CABLE 9637

For the PC, 9 pin - 9 pin, cross, 1.8 m (5.91 ft) length

RS-232C CABLE 9638

For the PC, 9 pins - 25 pins, cross, 1.8m (5.91 ft) length

Probe and Test fixtures

 

TEST FIXTURE 9262

Direct connection type, DC to 8 MHz, measurable conductor diameter: ø0.3 (0.01 in) to 2 mm (0.08 in)

SMD TEST FIXTURE 9263

Direct connection type, DC to 8 MHz, Test sample dimensions:1 mm (0.04 in) to 10 mm (0.39 in)

4-TERMINAL PROBE 9140

DC to 100 kHz, 1 m (3.28 ft) length, impedance characteristics of 75 Ω

4-TERMINAL PROBE 9500

DC to 1 MHz, 1 m (3.28 ft) length

There are no drivers, firmware or software available for this product.