fbpx

RESISTANCE HiTESTER RM3542

Home/Resistance Meters/RESISTANCE HiTESTER RM3542

RESISTANCE HiTESTER RM3542

Wide Range 100 mΩ to 100 MΩ DC Resistance Meter with Low Power Resistance Mode for Testing Chip Inductors and EMC Suppression Components on Production Lines

SKU: RM3542 Category:

Model No. (Order Code)

RM3542 basic model
RM3542-01 with GP-IB interface

Note: Test fixtures are not supplied with the unit. Please select an optional test fixture when ordering

CE
GPIB
RS232C

 

Description

Hioki DC resistance meters measure a broad range of resistance values at a high level of precision. The RM3542 deliver high speed, high precision, and high reliability, indispensable for the shipping inspection of devices such as resistors and EMI components. The resistance meter also supports chip resistor sampling inspections, helping resistor manufacturers improve productivity.

 

 

Key Features

• High speed and accuracy maximize productivity in automated systems
• Multiple checking functions ensure proper contact for reliable measurements
• Low-power resistance mode measures chip inductors and EMC suppression components
• Supports sample inspections during the manufacturing process

 

 

Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)

Resistance range [at Low Power OFF] 100 mΩ range (Max. 120.0000 mΩ, 0.1 μΩ resolution) to 100 MΩ range (Max. 120.0000 MΩ, 100 Ω resolution), 10 steps
[at Low Power ON] 1000 mΩ range (Max. 1200.000 mΩ, 1 μΩ resolution) to 1000 Ω range (Max. 1200.000 Ω, 1 mΩ resolution), 4 steps
Display Monochrome graphic LCD 240 × 64 dot, white LED backlight
Measurement accuracy [with SLOW mode, at 100 mΩ range] ±0.015 % rdg. ±0.002 % f.s.
[with SLOW mode, at 1000 Ω range] ±0.006 % rdg. ±0.001 % f.s. (the best case)
Testing current [at 100 mΩ range] 100 mA DC to [at 100 MΩ range] 100 nA DC
Open-terminal voltage 20 V DC max.
Sampling rate FAST, MEDIUM, SLOW, 3 settings
Measurement times [at 100 Ω /1000 Ω ranges, with Low Power OFF]
FAST: 0.9 ms, MED: 3.6 ms, SLOW: 17 ms (minimum time)
Integration time 0.1 ms to 100.0 ms, or 1 to 5 PLC at 50 Hz, 1 to 6 PLC at 60 Hz
Note: PLC = one power line cycle (mains wave-form period)
Other functions Comparator (compare setting value with measurement value), Delay (set to allow for mechanical delay of trigger input and probing, or set to allow for measurement object response), OVC (offset voltage compensation), Measurement fault detection, Probe short-circuit detection, Improve contact, Auto-memory, Statistical calculations, Settings monitor (when using two instruments, a difference in settings causes warning notification), Retry, Trigger function. etc,.
Interfaces RS-232C, Printer, GP-IB (Model RM3542-01)
External I/O Trigger, Hold input, Comparator output, Settings monitor terminal
Power supply 100 to 240 V AC, 50/60 Hz, 30 VA max.
Dimensions and mass 260 mm (10.24 in) W × 88 mm (3.46 in) H × 300 mm (11.81 in) D, 2.9 kg (102.3 oz)
Accessories Power cord ×1, EXT. I/O male connector ×1, Instruction manual ×1, Operation guide ×1

Catalogs

RESISTANCE METER RM3542A, RM3542

User Guides

Technical Note: Shunt Resistor Measurement Vol.5

Technical Note: Wide or Thick Resistor Measurement Vol.4

Technical Note: Introduction to Resistance Measurement Vol.1

Declaration of Conformity

RESISTANCE HiTESTER RM3542,RM3542-01 [121KB]

Options

PC communication

 

GP-IB CONNECTOR CABLE 9151-02

2 m (6.56 ft) length

RS-232C CABLE 9637

For the PC, 9 pin - 9 pin, cross, 1.8 m (5.91 ft) length

RS-232C CABLE 9638

For the PC, 9 pins - 25 pins, cross, 1.8m (5.91 ft) length

Probe and Test fixtures

 

TEST FIXTURE 9262

Direct connection type, DC to 8 MHz, measurable conductor diameter: ø0.3 (0.01 in) to 2 mm (0.08 in)

SMD TEST FIXTURE 9263

Direct connection type, DC to 8 MHz, Test sample dimensions:1 mm (0.04 in) to 10 mm (0.39 in)

4-TERMINAL PROBE 9140

DC to 100 kHz, 1 m (3.28 ft) length, impedance characteristics of 75 Ω