fbpx

MEMORY HiCORDER MR8870

Home/Data Acquisition Oscilloscopes/MEMORY HiCORDER MR8870

MEMORY HiCORDER MR8870

A Single Memory Recorder that can Observe Waveforms like an Oscilloscope and Record RMS Value Fluctuations

Model No. (Order Code)

MR8870-20 2ch, English model

Note: Input cords and battery pack are not included. Purchase the cords appropriate for your application separately. The AC Adapter Z1005 is included as standard.

USB 2.0
CE

 

Description

Hioki Memory HiCorders are high-speed waveform monitoring and recording devices that can simultaneously measure multiple quick-changing phenomena due to complete isolation between channels and from each channel to the ground. The MR8870 is a handheld data acquisition (DAQ) recorder built in with 2 analog channels and 2MW of memory, suitable for elevator maintenance, machine, motor and inverter fault analysis, testing and inspections.

Key Features
• Mode for recording instantaneous waveform and RMS fluctuations
• Save values in real time to a CF card
• Record four channels at once by synchronizing two instruments with the bundled PC application
• Compact and easy to carry
• Easy, intuitive operation
• Fast, 1MS/s performance despite the compact size
• Built-in, compact-yet-sharp QVGA-TFT wide LCD

 

 

Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)

Number of channels 2 analog channels + 4 logic channels (standard)
Note: Isolated analog channels, isolated input and frame, logic has common GND
Measurement ranges 10 mV to 50 V/div (10 div full-scale), 12 ranges, Resolution: 1/100 of range
Max. rated voltage Between terminals: 400 VDC, Between terminal to earth: 300 VAC, DC CAT II
Frequency characteristics DC to 50 kHz (-3 dB)
Time axis (Memory mode) 100 µs to 5 min/div, 20 ranges,at 100 points/div resolution, three steps of time-axis magnification from ×2 to ×10, and 9 steps of time-axis compression from ×1/2 to ×1/1,000
Recording intervals (RMS mode) 1 ms to 1 min., 16 settings, sampling period: 200 μs (fixed) (for AC voltage/current, 1,000 RMS values/sec.), envelope mode always on
Note: Only the maximum value and minimum value for each recording interval are recorded.
Measurement functions Memory recorder (high speed recording), RMS recorder (50/60 Hz, DC only)
Memory capacity 12-bits × 2M-words/ch (1 word = 2 bytes)
Removable storage CF card TYPE I slot ×1 (Up to 2 GB)
Display 4.3-inch WQVGA-TFT color LCD (480 × 272 dots)
Displayable languages English, Japanese
Interfaces USB 2.0 mini-B receptacle ×1, Functionality: Connect the instrument to a PC to send files on the CF card to the PC. The instrument cannot be controlled from a PC.
Printer N/A
Power supply AC Adapter Z1005: 100 to 240 VAC (50/60 Hz) , 30 VA max. (when using the AC adapter and charging the 9780 with the instrument)
Battery Pack 9780: 3 VA, continuous operating time of approx. 2 hr. (25°C reference value; when used with the Z1005, the Z1005 takes priority), charging time of 200 min. using the AC adapter (25°C reference value) (option)
External DC power: 10 to 16 V, 10 VA max. (connection cord of 3 m or less is available by special-order)
Dimensions and mass 176 mm (6.93 in)W × 101 mm (3.98 in)H × 41 mm (1.61 in)D, 600 g (21.2 oz) (with the Battery pack 9780 installed)
Accessories Instruction manual ×1, Measurement guide ×1, AC adapter Z1005 ×1, Strap ×1, USB cable ×1, Application disk (Dedicated program for the MR8870) ×1, Protection sheet 9809 ×1

LabVIEW and MATLAB support

Compatible models LabVIEW MATLAB script
MR8870-20 N/A N/A

Catalogs

DIFFERENTIAL PROBE P9000

MR8870-20 2 Channel Memory Recorder

NON-CONTACT AC VOLTAGE PROBE SP3000

Declaration of Conformity

MEMORY HiCORDER MR8870-20 [100KB]

Options

100 A to 2000 A (Medium speed) A

 

DISPLAY UNIT CM7291

• Built in Bluetooth® Smart • Use with CT7000 series Current sensor • DCA, ACA, (DC+AC)A, frequency • Output to oscilloscopes: WAVE, RMS, PEAK, Hz • Power supply for single sensor

DISPLAY UNIT CM7290

• Use with CT7000 series Current sensor • DCA, ACA, (DC+AC)A, frequency • Output to oscilloscopes: WAVE, RMS, PEAK, Hz • Power supply for single sensor

AC/DC AUTO-ZERO CURRENT SENSOR CT7742

・ DC to 5 kHz (-3dB) ・ Rated 2000 A AC/DC ・ 0.1mV/A output ・φ 55 mm (2.17 in) core dia.

AC/DC AUTO-ZERO CURRENT SENSOR CT7736

・ DC to 5 kHz (-3dB) ・ Rated 600 A AC/DC ・1mV/A output ・φ 33 mm (1.30 in) core dia.

AC/DC AUTO-ZERO CURRENT SENSOR CT7731

・ DC to 5 kHz (-3dB) ・ Rated 100 A AC/DC ・ 1mV/A output ・φ 33 mm (1.30 in) core dia.

AC/DC CURRENT SENSOR CT7642

・ DC to 10kHz (-3dB) ・Rated 2000 A AC/DC ・ 0.1mV/A output ・φ 55 mm (2.17 in) core dia.

AC/DC CURRENT SENSOR CT7636

・ DC to 10kHz (-3dB) ・Rated 600 A AC/DC ・ 1mV/A output ・φ 33 mm (1.30 in) core dia.

AC/DC CURRENT SENSOR CT7631

・ DC to 10kHz (-3dB) ・Rated 100 A AC/DC ・ 1mV/A output ・φ 33 mm (1.30 in) core dia.

500 A to 5000 A

*For commercial power lines, 50/60 Hz

 

AC FLEXIBLE CURRENT SENSOR CT9667

• 10 Hz to 20 kHz (±3dB) • 5000 A/ 500 A AC rated input • 500 mV/f.s. output • φ 100 mm (3.94 in) core dia. to φ 254 mm (10.00 in), 3 loop diameters

CLAMP ON PROBE 9132-50

• Use for level measurement • 40 Hz to 1 kHz • 20 to 1000A AC • 0.2 V AC/range output • φ 55 mm (2.17 in) core dia.

CLAMP ON PROBE 9018-50

• Excellent phase characteristics • 40 Hz to 3 kHz • 10 to 500A AC • 0.2V AC/range output • φ 46 mm (1.81 in) core dia.

Input cable (A)

*Voltage is limited to the specifications of the input modules in use.

 

CONNECTION CORD L9790

• Flexible φ 4.1 mm (0.16 in) thin dia. • Cable allowing for up to 600 V input • 1.8 m (5.91 ft) length

ALLIGATOR CLIP L9790-01

Red/black set attaches to the ends of the Connection Cord L9790

GRABBER CLIP 9790-02

Red/black set attaches to the ends of the Connection Cord L9790

CONTACT PIN 9790-03

Red/black set attaches to the ends of the Connection Cord L9790

Input cable (B)

*Voltage is limited to the specifications of the input modules in use.

 

CONNECTION CORD L9197

•φ 5.0 mm (0.20 in) dia •Cable allows for up to 600 V input •1.8 m (5.91 ft) length •Includes detachable large alligator clips

CONNECTION CORD L9198

•φ 5.0 mm (0.20 in) dia. •Cable allows for up to 300 V input •1.7 m (5.58 ft) length •Small alligator clip

GRABBER CLIP 9243

Attaches to the tip of the banana plug cable, Red/ Black: 1 each, 196 mm (7.72 in) length, CAT III 1000 V

Input cable (D)

* Voltage to ground is within this product’s specifications, separate power source is also required.

 

AC ADAPTER Z1008

100 to 240V AC

DIFFERENTIAL PROBE P9000

• Waveform only for exclusive use with Memory HiCorders (P9000-01) or waveform/RMS value switchable (P9000-02) • For use with input of up to 1 kV AC/DC • Requires separate power supply

Input cable (E)

*Voltage to ground is within this product's specifications. Separate power source is also required.

 

AC ADAPTER 9418-15

100 to 240V AC

DIFFERENTIAL PROBE 9322

• For up to 2 kV DC or 1 kV AC • Use with AC Adapter 9418-15 • Frequency band width up to 10MHz

Leak Current

*For commercial power lines, 50/60 Hz

 

CLAMP ON LEAK HiTESTER 3283

• True RMS • AC leak current and load current testing • 10 mA leak current range with 10 µA resolution • Load current up to 200 A

AC ADAPTER 9445-02

For USA, 100 to 240 V AC, 9 V/ 1 A

OUTPUT CORD L9095

Connect to BNC terminal, 1.5 m (4.92 ft) length

OUTPUT CORD L9094

3.5 mm (0.14 in) dia. mini plug to banana, 1.5 m (4.92 ft) length

Logic signal measurement

* Only the small terminal types can be used. * The 9323 is not required for the small-terminal types 9327, 9320-01, 9321-01 and MR9321-01.

 

CONVERSION CABLE 9323

• Used for connecting the 9320/9321/MR9321 and the 9324 to the Memory HiCorder with small logic terminal models

LOGIC PROBE MR9321,MR9321-01

• 4 isolated channels • ON/OFF detection of AC/DC voltage • Large terminal type

LOGIC PROBE 9320-01,9320

• 4 channels for contact voltage signals • 500ns response • Miniature terminal type

Non-contact Voltage measuring

 

NON-CONTACT AC VOLTAGE PROBE SP3000

Sold individually

NON-CONTACT AC VOLTAGE PROBE SP3000-01

• Supports φ1mm to 2.5mm covered wires • 10Hz to 100kHz frequency bandwidth • 5Vrms 14Vp-p rated measurement voltage

AC VOLTAGE PROBE SP9001

Sold individually

Other options

 

SOFT CASE 9812

Includes space for small items, neoprene rubber

CARRYING CASE 9782

Includes compartment for options, resin-coated

PROTECTION SHEET 9809

For LCD protection, pairs of sheets

Other options for Input

 

CONVERSION ADAPTER 9199

Receiving side banana, output BNC terminal

CONNECTION CORD L9217

Cord has insulated BNC connectors at both ends, 1.6 m (5.25 ft) length

PL23 (10-pin) - ME15W (12-pin) conversion

 

CONVERSION CABLE CT9900

Convert PL23 (10-pin) terminal to ME15W (12-pin) terminal

Power supply

*Not necessary when using Current Unit 8971.

 

AC ADAPTER Z1005

100 to 240 V AC

BATTERY PACK 9780

NiMH, Charges while installed in the main unit

POWER SUPPLY for Current Sensors

*A separate power supply (CT955x) is required in order to use a high-precision current sensor.

 

SENSOR UNIT CT9557

• Power supply for current sensors when used alone • 4ch, with Waveform/Total Waveform/Total RMS output

SENSOR UNIT CT9556

• Power supply for current sensors when used alone • 1ch, with Waveform/RMS output

SENSOR UNIT CT9555

• Power supply for current sensors when used alone • 1ch, with Waveform output

Storage media

*The CF card includes a PC card adapter. PC Card Precaution Use only PC Cards sold by HIOKI. Compatibility and performance are not guaranteed for PC cards made by other manufacturers. You may be unable to read from or save data to such cards.

 

PC CARD 9830

• 2 GB capacity • PC card adapter bundled

PC CARD 1G 9729

• 1 GB capacity • PC card adapter bundled

PC CARD 512M 9728

• 512 MB capacity • PC card adapter bundled

Up to 1000 A (High precision)

 

AC/DC CURRENT PROBE CT6846

• DC to 20 kHz • 1000 A AC/DC rated • 2 mV/A output • φ 50 mm (1.79 in) core dia.

AC/DC CURRENT PROBE CT6844

• DC to 200 kHz • 500 A AC/DC rated • 4 mV/A output • φ 20 mm (0.79 in) core dia.

AC/DC CURRENT PROBE CT6845

• DC to 100 kHz • 500 A AC/DC rated • 4 mV/A output • φ 50 mm (1.79 in) core dia.

AC/DC CURRENT SENSOR 9709

• DC to 100kHz • Phase: DC to 100kHz • Rated 500A • 2V/500A output • φ 36 mm (1.42 in) core dia.

Up to 200 A (High precision)

 

CLAMP ON SENSOR 9272

• 1Hz to 100kHz • Phase: 5Hz to 50kHz • Rated 20A or 200A • 2V/20A, 2V/200A output • φ 46 mm (1.81 in) core dia.

AC/DC CURRENT PROBE CT6843

• Frequency characteristics DC to 500 kHz, 200A AC/DC rated, 0.01 V/A output • φ 20 mm (0.79 in) core dia.

AC/DC CURRENT PROBE CT6841

• Frequency characteristics DC to 1 MHz, 20A AC/DC rated, 0.1 V/A output • φ 20 mm (0.79 in) core dia.

AC/DC CURRENT SENSOR CT6863

• DC to 500 kHz, Phase: DC to 300kHz • Rated 200A • 2V/200A output • φ 24 mm (0.94 in) core dia.

AC/DC CURRENT SENSOR CT6862

• DC to 1MHz, Phase: DC to 300kHz • Rated 50A • 2V/50 A output • φ 24 mm (0.94 in) core dia.

Power Failure Test of Uninterruptible Power Supply (UPS) Systems 

Measure the Instantaneous Power Failure and Voltage Drop of Utility 

Drivers, Firmware, Software