fbpx

MEMORY HiCORDER 8860, 8861

Exclusive Academic Offer

MEMORY HiCORDER 8860, 8861

High-speed 16- or 32-channel Memory Recorders Offer Data Acquisition, Oscilloscope and Data Logger Functionality to Record Waveforms in Any Situation

Model No. (Order Code)

8860-51 Main unit only, input modules up to 4 units
8861-51 Main unit only, input modules up to 8 units
8860-50 Discontinued
8861-50 Discontinued

Note: The 8860-51 and 8861-51 cannot operate alone. You must install one or more optional input modules in the unit. Note: Memory boards are not built-in as a standard feature. Choose one board for Model 8860-51, and two of the same capacity for the 8861-51, for factory pre-installation.

LAN
USB 2.0
CE

 

Description

Hioki Memory HiCorders are high-speed waveform monitoring and recording devices that can simultaneously measure multiple physical phenomena such as voltage, current, temperature, vibration, weight, acceleration and rotation due to complete isolation between channels and from each channel to the ground. More than just a digital oscilloscope, the 8860-50 and 8861-50 memory recorders accommodate plug-and-play input modules to meet applications such as monitoring commercial power supplies, fault analysis of electrical equipment, evaluating electric vehicle chargers, and analyzing conveyor belt speeds.

Key Features
• Built-in 80GB hard drive (no PC card slot)
• A faster CPU greatly enhances instrument operability and response.
• Multi-channel logging on up to 64 or 128 channels (Use with the 8958)
• 20 MS/s high-speed sampling (Use with the 8956)
• Various interfaces built-in: LAN/USB/Hard disk drive
• Supports the new high-voltage input module for measuring high voltage directly

 

 

Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)

  8860-51 8861-51
Number of input units Max. 4 units Max. 8 units
Number of channels Max. 16 analog channels (Max. 64 channels when using the 8958) + standard 16 logic channels Max. 32 analog channels (Max. 128 channels when using the 8958) + standard 16 logic channels
Measurement ranges (20 div full-scale) 5 mV to 20 V/div, 12 ranges (when using the 8956), Resolution : 1/100 of range 5 mV to 20 V/div, 12 ranges (when using the 8956), Resolution : 1/100 of range
Max. allowable input DC 400V (when using the 8956) DC 400V (when using the 8956)
Frequency characteristics DC to 10 MHz (-3dB, when using the 8956) DC to 10 MHz (-3dB, when using the 8956)
Time axis at memory function 5 µs to 5 min/div, 26 ranges, sampling period : 1/100 of range, external sampling, dual timebase possible
Measurement functions MEM (high-speed recording) REC (real-time recording) REC & MEM (realtime recording + high-speed recording) FFT (frequency analysis) Real-time Save (records directly to storage media)
Storage memory capacity 12-bits × 32M-words/ch (1ch at 8860-51, 2ch at 8861-51) to 2M-words/ch (16ch at 8860-51, 32ch at 8861-51)
*Memory capacity can be expanded 32 times. (Optional memory board)
Removable storage USB 2.0 memory ×3, Hard disk drive (80 GB, built in the main unit) ×1 (No PC card slot)
Recording paper [Built in optional printer unit] A4: 216 mm (8.50 in) × 30 m (98.43 ft), or A6: 112 mm (4.41 in) × 18 m (59.06 ft) selectable, thermal paper roll, Recording speed : Max. 25 mm (0.98 in)/sec
Display 10.4-inch SVGA-TFT color LCD (800 × 600 dots)
External interfaces USB 2.0, LAN, Monitor output (15 pin D-sub output), *GP-IB is Not Available
Power supply 100 to 240 V AC (50/60 Hz) (220 VA max. printer not used)
12 V DC (use the DC power unit 9684 : option, factory installation only)
100 to 240 V AC (50/60 Hz) (280 VA max. printer not used)
12 V DC (use the DC power unit 9684 : option, factory installation only)
Dimensions and mass 330 mm (12.99 in) W × 250 mm (9.84 in) H × 184.5 mm (7.26 in) D, 8 kg (282.2 oz) (printer not installed) 330 mm (12.99 in) W × 250 mm (9.84 in) H × 284.5 mm (11.20 in) D, 10.5 kg (370.4 oz) (printer not installed)
Accessories Quick Start Manual × 1, Input Module Guide × 1, Instruction Manual × 1, Analysis and Communication Supplement × 1, Application Disk (WaveViewer Wv, communication commands table) × 1, Power cord × 1, Input cord label × 1, Ferrite clamp (for LAN cable) × 1

LabVIEW and MATLAB support

Compatible models LabVIEW MATLAB script
8860-50 Available Available
8861-50 Available Available

Catalogs

DIFFERENTIAL PROBE P9000

NON-CONTACT AC VOLTAGE PROBE SP3000

REC&MEM Function, New Recording Logger and Oscilloscope

Declaration of Conformity

MEMORY HiCORDER 8860-50,8860-51,8861-50,8861-51 [110KB]

Others

Measuring Instruments for the Automotive Market

Options

10 mA class to 500 A (High speed)

 

CLAMP ON PROBE 3273-50

• DC to 50MHz (-3dB) • 30Arms maximum input • 0.1V/A output • φ 5 mm (0.20 in) core dia.

CLAMP ON PROBE 3276

• DC to 100MHz (-3dB) • 30Arms maximum input • 0.1V/A output • φ 5 mm (0.20 in) core dia.

CLAMP ON PROBE 3274

• DC to 10MHz (-3dB) • 150Arms maximum input • 0.01V/A output • φ 20 mm (0.79 in) core dia.

CLAMP ON PROBE 3275

• DC to 2MHz (-3dB) • 500Arms maximum input • 0.01V/A output • φ 20 mm (0.79 in) core dia.

100 A to 2000 A (Medium speed) A

 

AC/DC AUTO-ZERO CURRENT SENSOR CT7736

・ DC to 5 kHz (-3dB) ・ Rated 600 A AC/DC ・1mV/A output ・φ 33 mm (1.30 in) core dia.

AC/DC AUTO-ZERO CURRENT SENSOR CT7742

・ DC to 5 kHz (-3dB) ・ Rated 2000 A AC/DC ・ 0.1mV/A output ・φ 55 mm (2.17 in) core dia.

DISPLAY UNIT CM7290

• Use with CT7000 series Current sensor • DCA, ACA, (DC+AC)A, frequency • Output to oscilloscopes: WAVE, RMS, PEAK, Hz • Power supply for single sensor

AC/DC AUTO-ZERO CURRENT SENSOR CT7731

・ DC to 5 kHz (-3dB) ・ Rated 100 A AC/DC ・ 1mV/A output ・φ 33 mm (1.30 in) core dia.

AC/DC CURRENT SENSOR CT7631

・ DC to 10kHz (-3dB) ・Rated 100 A AC/DC ・ 1mV/A output ・φ 33 mm (1.30 in) core dia.

AC/DC CURRENT SENSOR CT7636

・ DC to 10kHz (-3dB) ・Rated 600 A AC/DC ・ 1mV/A output ・φ 33 mm (1.30 in) core dia.

AC/DC CURRENT SENSOR CT7642

・ DC to 10kHz (-3dB) ・Rated 2000 A AC/DC ・ 0.1mV/A output ・φ 55 mm (2.17 in) core dia.

500 A to 5000 A

*For commercial power lines, 50/60 Hz

 

CLAMP ON PROBE 9018-50

• Excellent phase characteristics • 40 Hz to 3 kHz • 10 to 500A AC • 0.2V AC/range output • φ 46 mm (1.81 in) core dia.

CLAMP ON PROBE 9132-50

• Use for level measurement • 40 Hz to 1 kHz • 20 to 1000A AC • 0.2 V AC/range output • φ 55 mm (2.17 in) core dia.

AC FLEXIBLE CURRENT SENSOR CT9667

• 10 Hz to 20 kHz (±3dB) • 5000 A/ 500 A AC rated input • 500 mV/f.s. output • φ 100 mm (3.94 in) core dia. to φ 254 mm (10.00 in), 3 loop diameters

Cases

 

CARRYING CASE 9723

For the 8860-50//-51/8860, hard trunk type

Current sensors for the F/V Unit 8940

*To connect the current sensor via the conversion cable for the F/V Unit 8940, or using with the Power supply unit 9555-10.

 

CONVERSION CABLE 9705

0.2 m (0.66 ft) length, to connect the CT6841-6846, CT6863/6865, 9709, 9272-10 to the F/V Unit 8940, Cannot be used in combination with the CT6862

CONVERSION CABLE 9319

To connect the 3273-50 and the 8940, Note: cannot be used with the 3274, 3275, 3276 to connect the 8940 via this cable 9319

Factory options (B)

*Must specify when ordering

 

DC POWER UNIT 9684

Built in on the bottom case. 12 V DC drive.

Factory options (C)

*Must specify when ordering

 

PROBE POWER UNIT 9687

Factory-installed option - not user installable, built in on the bottom case. Simultaneously power up to at least 5 units of Clamp on Probes 3273-50 to 3276 or Differential Probe 9322. (Actual number depends on combination of probes.)

Factory-installed options (A)

*Must specify when ordering

 

MEMORY BOARD 9715-50

32 Megaword capacity

MEMORY BOARD 9715-51

128 Megaword capacity

MEMORY BOARD 9715-52

512 Megaword capacity

MEMORY BOARD 9715-53

1 Gigaword capacity

HD UNIT 9718-50

Built in type, 80 GB

MEMORY BACKUP UNIT 9719-50

Built in type

Input cable (A)

*Voltage is limited to the specifications of the input modules in use.

 

CONNECTION CORD L9790

• Flexible φ 4.1 mm (0.16 in) thin dia. • Cable allowing for up to 600 V input • 1.8 m (5.91 ft) length

CONTACT PIN 9790-03

Red/black set attaches to the ends of the Connection Cord L9790

GRABBER CLIP 9790-02

Red/black set attaches to the ends of the Connection Cord L9790

ALLIGATOR CLIP L9790-01

Red/black set attaches to the ends of the Connection Cord L9790

Input cable (B)

*Voltage is limited to the specifications of the input modules in use.

 

GRABBER CLIP 9243

Attaches to the tip of the banana plug cable, Red/ Black: 1 each, 196 mm (7.72 in) length, CAT III 1000 V

CONNECTION CORD L9198

•φ 5.0 mm (0.20 in) dia. •Cable allows for up to 300 V input •1.7 m (5.58 ft) length •Small alligator clip

CONNECTION CORD L9197

•φ 5.0 mm (0.20 in) dia •Cable allows for up to 600 V input •1.8 m (5.91 ft) length •Includes detachable large alligator clips

Input cable (D)

* Voltage to ground is within this product’s specifications, separate power source is also required.

 

AC ADAPTER Z1008

100 to 240V AC

DIFFERENTIAL PROBE P9000

• Waveform only for exclusive use with Memory HiCorders (P9000-01) or waveform/RMS value switchable (P9000-02) • For use with input of up to 1 kV AC/DC • Requires separate power supply

Input cable (E)

*Voltage to ground is within this product's specifications. Separate power source is also required.

 

POWER CORD 9248

Power supply to the 9322 through this cord from the Probe power unit 9687, 70 cm (2.30 ft) length

AC ADAPTER 9418-15

100 to 240V AC

DIFFERENTIAL PROBE 9322

• For up to 2 kV DC or 1 kV AC • Use with AC Adapter 9418-15 • Frequency band width up to 10MHz

Input cord (C)

* This probe does not expand the maximum rated voltage above ground of an isolated input.

 

100:1 PROBE, 10:1 PROBE 9666, 9665

•Max. rated voltage to earth is same as for input module •1.5 m (4.92 ft) length •Max. input voltage: 9666: 5 kV peak (up to 1MHz); 9665: 1 kV rms (up to 500 kHz)

Input modules

*Input cords are not included. Please purchase them separately. *When using 9709 with Current Unit 8971, a total of 7 current probes can be used.

 

16ch SCANNER UNIT 8958

16 ch, Voltage or Temperature input with thermocouple

DC/RMS UNIT 8959

2 ch, Voltage, DC to 400 kHz, or RMS rectifier DC/20 to 100 kHz

STRAIN UNIT 8960

2 ch, Distortion measurement for strain gauge converter

HIGH VOLTAGE UNIT 8961

2 ch, Voltage input, DC/RMS selectable, bundled input cables

HIGH RESOLUTION UNIT 8957

2 ch, Voltage input, DC to 200 kHz bandwidth, built in filter for FFT

ANALOG UNIT 8956

2 ch, Voltage input, DC to 10 MHz bandwidth

ANALOG UNIT 8936

2 ch, Voltage input, DC to 400 kHz bandwidth

VOLTAGE/TEMP UNIT 8937

2 ch, Voltage or Temperature input with thermocouple

STRAIN UNIT 8939

2 ch, Distortion measurement for strain gauge converter, not CE Marked

F/V UNIT 8940

2 ch, Frequency, Voltage input, Current input with clamp-on sensor

4ch ANALOG UNIT 8946

4 ch, Low voltage input, DC to 100 kHz bandwidth

CHARGE UNIT 8947

2 ch, Charge-output type piezoelectric acceleration pick-up sensor, Acceleration pick-up sensor with an internal preamp

Leak Current

*For commercial power lines, 50/60 Hz

 

CLAMP ON LEAK HiTESTER 3283

• True RMS • AC leak current and load current testing • 10 mA leak current range with 10 µA resolution • Load current up to 200 A

AC ADAPTER 9445-02

For USA, 100 to 240 V AC, 9 V/ 1 A

OUTPUT CORD 9094

3.5 mm (0.14 in) dia. mini plug to banana, 1.5 m (4.92 ft) length

Logic signal measurement

* Only the small terminal types can be used. * The 9323 is not required for the small-terminal types 9327, 9320-01, 9321-01 and MR9321-01.

 

LOGIC PROBE 9327

• 4 channels for contact voltage signals • High-speed 100ns response

LOGIC PROBE 9320-01,9320

• 4 channels for contact voltage signals • 500ns response • Miniature terminal type

LOGIC PROBE MR9321,MR9321-01

• 4 isolated channels • ON/OFF detection of AC/DC voltage • Large terminal type

CONVERSION CABLE 9323

• Used for connecting the 9320/9321/MR9321 and the 9324 to the Memory HiCorder with small logic terminal models

Non-contact Voltage measuring

 

NON-CONTACT AC VOLTAGE PROBE SP3000

Sold individually

NON-CONTACT AC VOLTAGE PROBE SP3000-01

• Supports φ1mm to 2.5mm covered wires • 10Hz to 100kHz frequency bandwidth • 5Vrms 14Vp-p rated measurement voltage

AC VOLTAGE PROBE SP9001

Sold individually

Other options for Input

 

CONNECTION CORD L9217

Cord has insulated BNC connectors at both ends, 1.6 m (5.25 ft) length

CONNECTION CORD 9165

Cord has metallic BNC connectors at both ends, use at metallic terminal, 1.5 m (4.92 ft) length

CONVERSION CABLE 9318

To connect the CT6841-6846, CT6865/63/62, 9709, 9272-10 to the 8971/40/51, 38 cm (14.96 in) length

CONVERSION ADAPTER 9199

Receiving side banana, output BNC terminal

PC Software

 

LAN CABLE 9642

Straight Ethernet cable, supplied with straight to cross conversion adapter, 5 m (16.41 ft) length

WAVE PROCESSOR 9335

• Convert data, print and display waveforms

MEMORY HiVIEWER 9725

• Achieve functions identical to those of the Memory HiCorder 8860 Series on a PC

Power supply

*Not necessary when using Current Unit 8971.

 

POWER SUPPLY 3272

• For Hioki wide bandwidth current probes • Single sensor connectable

POWER SUPPLY 3269

• For Hioki wide bandwidth current probes • Connect up to four sensors

Printer options

*PRINTER UNIT is a built-in option that must be specified upon order.

 

A4 PRINTER UNIT 8995

Factory-installed option. Either 8995 or 8995-01 printer can be installed. Printing width 200 mm (7.87 inch). Compatible recording paper: Model 9231

A6 PRINTER UNIT 8995-01

Factory-installed option. Either 8995 or 8995-01 printer can be installed. Printing width 100 mm (3.94 inch). Compatible recording paper: Model 9234

RECORDING PAPER 9234

A6 width 112 mm (4.41 in) × 18 m (59.06 ft), 10 rolls/set

RECORDING PAPER 9231

A4 width 216 mm (8.50 in) × 30 m (98.43 ft), 6 rolls/set

Up to 1000 A (High precision)

 

AC/DC CURRENT PROBE CT6846

• DC to 20 kHz • 1000 A AC/DC rated • 2 mV/A output • φ 50 mm (1.79 in) core dia.

AC/DC CURRENT PROBE CT6844

• DC to 200 kHz • 500 A AC/DC rated • 4 mV/A output • φ 20 mm (0.79 in) core dia.

AC/DC CURRENT SENSOR 9709

• DC to 100kHz • Phase: DC to 100kHz • Rated 500A • 2V/500A output • φ 36 mm (1.42 in) core dia.

AC/DC CURRENT PROBE CT6845

• DC to 100 kHz • 500 A AC/DC rated • 4 mV/A output • φ 50 mm (1.79 in) core dia.

Up to 200 A (High precision)

 

AC/DC CURRENT SENSOR CT6862

• DC to 1MHz, Phase: DC to 300kHz • Rated 50A • 2V/50 A output • φ 24 mm (0.94 in) core dia.

AC/DC CURRENT SENSOR CT6863

• DC to 500 kHz, Phase: DC to 300kHz • Rated 200A • 2V/200A output • φ 24 mm (0.94 in) core dia.

AC/DC CURRENT PROBE CT6841

• Frequency characteristics DC to 1 MHz, 20A AC/DC rated, 0.1 V/A output • φ 20 mm (0.79 in) core dia.

AC/DC CURRENT PROBE CT6843

• Frequency characteristics DC to 500 kHz, 200A AC/DC rated, 0.01 V/A output • φ 20 mm (0.79 in) core dia.

CLAMP ON SENSOR 9272

• 1Hz to 100kHz • Phase: 5Hz to 50kHz • Rated 20A or 200A • 2V/20A, 2V/200A output • φ 46 mm (1.81 in) core dia.

Recording and Monitoring of Conveyor Speeds 

Development and Evaluation of Electric Vehicle (EV) Quick Chargers 

Testing System Interconnection Protection Function of Power Conditioners 

Time-Varying Magnetic Field Measurement of IH Equipment 

Record Data during a Trial Run of a Railway Car (Train) 

Evaluate the Input/Output Characteristics of a Power Conditioner for Mega Solar Power Generation 

Drivers, Firmware, Software

Freeware
Version 1.40
Translate »