fbpx

LCR HiTESTER 3511-50

LCR HiTESTER 3511-50

Compact, dual-band 120Hz/1kHz LCR Meter for Integration into Automated Production Lines

Model No. (Order Code)

3511-50

Note: This product is not supplied with measurement probes or test fixtures. Please select and purchase the measurement probe or test fixture options appropriate for your application separately. For an RS-232C connection: A crossover cable for interconnection can be used. You can use the RS-232C CABLE 9637 without hardware flow control.

CE
GPIB
RS232C

 

Description

Hioki LCR Meters and Impedance Analyzers range from 1mHz to 3GHz devices to suit a wide range of applications in the testing of electronic components. The 3511-50 is a compact, general purpose LCR meter for on-board testing of capacitors and coils used in electrical equipment and devices such as automotive-related components.

 

 

Key Features

• High speed measurement: 5 ms (1 kHz) or 13 ms (120 Hz)
• Built-in high-speed comparator
• Measurement frequency: 1 kHz/120 Hz selectable
• From minute measurement with a maximum resolution of 0.01 pF to high-capacity measurement up to 1 F
• Print measured values and comparator results with the Printer 9442 (option)

 

 

Basic specifications (Accuracy guaranteed for 6 months, Post-adjustment accuracy guaranteed for 6 months)

Measurement parameters |Z|, θ, R, C, L, D (tanδ), Q
Measurement range |Z|, R: 10 mΩ to 200.00 MΩ θ: -90.00° to +90.00°
C (at 120 Hz): 9.40 pF to 999.99 mF, C (at 1 kHz): 0.940 pF to 99.999 mF
L (at 120 Hz): 14.00 µH to 200.00 kH, L (at 1 kHz): 1.600 µH to 20.000 kH
D: 0.0001 to 1.9900, Q: 0.85 to 999.99
Basic accuracy |Z| : ±0.08 % rdg. θ: ±0.05°
Measurement frequency 120 Hz or 1 kHz
Measurement signal level 50 mV, 500 mV, 1 V rms
Output impedance 50 Ω
Display LED (5-digit display, full-scale count depends on range)
Measurement time Fast: 13 msec, Normal: 90 msec, Slow: 400 msec. (at 120 Hz)
Fast: 5 msec, Normal: 60 msec, Slow: 300 msec. (at 1 kHz)
DC bias DC voltage/DC current can be superimposed on the measurement signal.
(Requires optional unit and external constant voltage source/constant current source.)
Functions Panel save and load function, External input/Output (EXT. I/O), GP-IB (option) or RS-232C interface
Power supply Selectable 100, 120, 220 or 240V AC ±10%, 50/60Hz, 20VA max.
Dimensions and mass 210 mm (8.27 in) W × 100 mm (3.94 in) H × 168 mm (6.61 in) D, 2.5 kg (88.2 oz)
Accessories Instruction manual × 1, Power cord × 1, Spare fuse × 1

Catalogs

Catalog: LCR METER Series

LCR HiTESTER 3511-50

SMD TEST FIXTURE IM9110

User Guides

LCR Application Guide

Declaration of Conformity

LCR HiTESTER 3511-50 [100KB]

Options

Other options for Input

 

CONNECTION CORD 9165

Cord has metallic BNC connectors at both ends, use at metallic terminal, 1.5 m (4.92 ft) length

PC communication

 

GP-IB CONNECTOR CABLE 9151-02

2 m (6.56 ft) length

GP-IB INTERFACE 9518-01

Built into rear panel

Printer options

*PRINTER UNIT is a built-in option that must be specified upon order.

 

PRINTER 9442

For printing numerical values 112 mm (4.41 in) paper width, not CE marked

AC ADAPTER 9443-02

For the Printer 9442, EU type

CONNECTION CABLE 9444

9 pin - 9 pin straight, 1.5 m (4.92 ft) length

RECORDING PAPER 1196

For the Printer 9442, 112 mm (4.41 in) × 25 m (82.03 ft), 10 rolls/set

Probe and Test fixtures

 

4-TERMINAL PROBE 9140

DC to 100 kHz, 1 m (3.28 ft) length, impedance characteristics of 75 Ω

TEST FIXTURE 9261

DC to 8 MHz, 1 m (3.28 ft) length, impedance characteristics of 75 Ω

CONNECTION CORD 9166

Metal BNC to clip, 1.5 m (4.92 ft) length

DC BIAS VOLTAGE UNIT 9268

42 Hz to 5 MHz, Max. allowable voltage: ± 40 V DC

DC BIAS CURRENT UNIT 9269

42 Hz to 100 kHz, Max. allowable current: ±2A DC

SMD TEST FIXTURE IM9110

• Direct connection two-terminal measurement type • DC to 1 MHz • Measurable sample sizes: 008004 (EIA)

PINCHER PROBE L2001

Cable length 73 cm (2.40 ft), DC to 8 MHz, impedance characteristics of 50 Ω, 4-terminal pair configuration, tip electrode spacing: 0.3 (0.01 in) to 6 mm (0.24 in)

SMD TEST FIXTURE IM9100

• Direct connection type • SMDs with electrodes on the bottom • DC to 8MHz • Measurable sample sizes: 01005 to 0402 (EIA)

TEST FIXTURE 9262

Direct connection type, DC to 8 MHz, measurable conductor diameter: ø0.3 (0.01 in) to 2 mm (0.08 in)

SMD TEST FIXTURE 9263

Direct connection type, DC to 8 MHz, Test sample dimensions:1 mm (0.04 in) to 10 mm (0.39 in)

SMD TEST FIXTURE 9677

Direct connection type, For measuring SMDs with electrodes on the side; DC to 120 MHz, test sample dimensions: 3.5 mm ±0.5 mm (0.14 in ±0.02 in)

SMD TEST FIXTURE 9699

Direct connection type, For measuring SMDs with electrodes on the bottom; DC to 120 MHz, test sample dimensions: 1.0 mm (0.04 in) to 4.0 mm (0.16 in) wide, max. 1.5 mm (0.06 in) high

CONTACT TIPS IM9901

To replace the tip on the L2001, regular size, bundled with the L2001

CONTACT TIPS IM9902

To replace the tip on the L2001, small size

Check the Deterioration of Oil Capacitors in Train Cars 

There are no drivers, firmware or software available for this product.

Translate »