IMPEDANCE ANALYZER IM3570

Home/LCR Meters Impedance Analyzers/IMPEDANCE ANALYZER IM3570
Exclusive Academic Offer

IMPEDANCE ANALYZER IM3570

Single Device Solution for High Speed Testing and Frequency Sweeping

SKU: IM3570 Category:

Model No. (Order Code)

IM3570

Note: This product is not supplied with measurement probes or test fixtures. Please select and purchase the measurement probe or test fixture options appropriate for your application separately. For an RS-232C connection: A crossover cable for interconnection can be used. You can use the RS-232C CABLE 9637 without hardware flow control.

LAN
USB 2.0
CE
GPIB
RS232C

 

Description

Hioki LCR Meters and Impedance Analyzers range from 1mHz to 3GHz devices to suit a wide range of applications in the testing of electronic components. The IM3570 is ideal for use in applications requiring low-ESR measurement on the order of several milliohms, for example testing of functional polymer capacitors, due to its superior low-impedance repeatability.

Key Features
• LCR measurement, DCR measurement, sweep measurement, continuous measurement and high-speed testing achieved with one instrument
• High-speed testing, achieving maximum speeds of 1.5ms (1 kHz) and 0.5ms (100kHz) in LCR mode
• High-accuracy measurements, basic accuracy of Z parameter: ± 0.08%
• Perfect impedance analyzer for testing the resonance characteristics of piezoelectric elements, C-D and low ESR measurement of functional polymer capacitors, DCR and L-Q measurement of inductors (coils and transformers)
• Perform frequency sweeps, level sweeps, and time interval measurements in analyzer mode

 

 

Impedance Analyzer IM3570: Measuring the resonance characteristics of a piezoelectric element

The IM3570, which serves as both an LCR meter and an impedance analyzer, can
generate pass/fail judgments on the resonance condition using its frequency
sweep measurement and peak comparator functions, and also conduct continuous
inspections under different conditions including pass/fail decisions via 1
kHz and 120 Hz LCR testing. In this way, it is possible to make both
frequency sweep measurement and LCR measurement with a single instrument.

 

 

Product Video

 

Application information

Download the sample application and view the Communications Command User Manual.

 

Click here for the LCR application.

Accuracy calculation information

Calculate accuracy by simply entering a numerical value.

 

Click here to calculate accuracy.

Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)

Measurement modes LCR mode, Analyzer mode (Sweeps with measurement frequency and measurement level), Continuous measurement mode
Measurement parameters Z, Y, θ, Rs (ESR), Rp, Rdc (DC resistance), X, G, B, Cs, Cp, Ls, Lp,
D (tanδ), Q
Measurement range 100 mΩ to 100 MΩ, 12 ranges (All parameters are determined according to Z)
Display range Z, Y, Rs, Rp, Rdc, X, G, B, Ls, Lp, Cs, Cp :
±(0.000000 [unit] to 9.999999G [unit], Absolute value display for Z and Y only
θ : ±(0.000° to 180.000°), D : ±(0.000000 to 9.999999)
Q : ±(0.00 to 99999.99), Δ % : ±(0.0000% to 999.9999%)
Basic accuracy Z ±0.08% rdg. θ: ±0.05°
Measurement frequency 4 Hz to 5 MHz (5 digits setting resolution, minimum resolution 10 mHz)
Measurement signal level Normal mode:
V mode/CV mode: 5 mV to 5 Vrms (up to 1 MHz)
10 mV to 1 Vrms (1.0001 MHz to 5 MHz), 1 mVrms steps
CC mode: 10 μA to 50 mArms (up to 1 MHz)
10 μA to 10 mArms (1.0001 MHz to 5 MHz), 10 μArms steps
Low impedance high accuracy mode:
V mode/CV mode: 5 mV to 1 Vrms (up to 100 kHz), 1 mVrms steps
CC mode:10 μA to 100 mArms (100 mΩ and 1Ω ranges of up to 100 kHz), 10 μArms steps
Output impedance Normal mode: 100 Ω, Low impedance high accuracy mode: 10 Ω
Display 5.7-inch color TFT, display can be set to ON/OFF
Measurement time 0.5 ms (100 kHz, FAST, display OFF, representative value)
Functions DC bias measurement, Comparator, BIN measurement (classification), Panel loading/saving, Memory function
Interfaces EXT I/O (handler), RS-232C, GP-IB, USB communication, USB memory, LAN
Power supply 90 to 264 V AC, 50/60 Hz, 150 VA max.
Dimensions and mass 330 mm (12.99 in) W × 119 mm (4.69 in) H × 307 mm (12.09 in) D, 5.8 kg (204.6 oz)
Accessories Power cord × 1, Instruction manual × 1, PC communication instruction manual (CD-R) × 1

Catalogs

Catalog: LCR METER Series

EQUIVALENT CIRCUIT ANALYSIS FIRMWARE IM9000

IMPEDANCE ANALYZER IM3570

SMD TEST FIXTURE IM9110

Declaration of Conformity

IMPEDANCE ANALYZER IM3570 [121KB]

Others

Measuring Instruments for the Automotive Market

Options

Factory-installed option

*Must specify when ordering

 

EQUIVALENT CIRCUIT ANALYSIS FIRMWARE IM9000

• Optional software for Model IM3570 • 5 equivalent circuit models • Plot frequency characteristics graph from analysis results • Cole-Cole plot, admittance circle display

PC communication

 

GP-IB CONNECTOR CABLE 9151-02

2 m (6.56 ft) length

Probe and Test fixtures

 

SMD TEST FIXTURE IM9110

• Direct connection two-terminal measurement type • DC to 1 MHz • Measurable sample sizes: 008004 (EIA)

PINCHER PROBE L2001

Cable length 73 cm (2.40 ft), DC to 8 MHz, impedance characteristics of 50 Ω, 4-terminal pair configuration, tip electrode spacing: 0.3 (0.01 in) to 6 mm (0.24 in)

4-TERMINAL PROBE L2000

Cable length 1 m (3.28 ft), DC to 8 MHz, impedance characteristics of 50 Ω, 4-terminal pair configuration, measurable conductor diameter: ø0.3 (0.01 in) to 5 mm (0.20 in)

CONTACT TIPS IM9902

To replace the tip on the L2001, small size

CONTACT TIPS IM9901

To replace the tip on the L2001, regular size, bundled with the L2001

SMD TEST FIXTURE 9699

Direct connection type, For measuring SMDs with electrodes on the bottom; DC to 120 MHz, test sample dimensions: 1.0 mm (0.04 in) to 4.0 mm (0.16 in) wide, max. 1.5 mm (0.06 in) high

SMD TEST FIXTURE 9677

Direct connection type, For measuring SMDs with electrodes on the side; DC to 120 MHz, test sample dimensions: 3.5 mm ±0.5 mm (0.14 in ±0.02 in)

4-TERMINAL PROBE 9500-10

Cable length 1 m (3.28 ft), DC to 200 kHz, impedance characteristics of 50 Ω, measurable conductor diameter: φ0.3 mm (0.01 in) to 2 mm (0.08 in)

DC BIAS CURRENT UNIT 9269-10

Direct connection type, 40 Hz to 2 MHz, maximum applied current of DC 2 A

DC BIAS VOLTAGE UNIT 9268-10

Direct connection type, 40 Hz to 8 MHz, maximum applied voltage of DC ±40 V

SMD TEST FIXTURE 9263

Direct connection type, DC to 8 MHz, Test sample dimensions:1 mm (0.04 in) to 10 mm (0.39 in)

TEST FIXTURE 9262

Direct connection type, DC to 8 MHz, measurable conductor diameter: ø0.3 (0.01 in) to 2 mm (0.08 in)

TEST FIXTURE 9261-10

Cable length 1 m (3.28 ft), DC to 8 MHz, impedance characteristics of 50 Ω, 4-terminal pair configuration, measurable conductor diameter: ø0.3 (0.01 in) to 1.5 mm (0.06 in)

4-TERMINAL PROBE 9140-10

Cable length 1 m (3.28 ft), DC to 200 kHz, impedance characteristics of 50 Ω, 4-terminal pair configuration, measurable conductor diameter: ø0.3 (0.01 in) to 5 mm (0.20 in)

SMD TEST FIXTURE IM9100

• Direct connection type • SMDs with electrodes on the bottom • DC to 8MHz • Measurable sample sizes: 01005 to 0402 (EIA)

Smart key/immobilizer antenna impedance measurements 

Pass/Fail Judgment of Passive Components such as Capacitors 

Test the Characteristics of Piezoelectric Elements at High Speeds 

Test the Characteristics of Functional Polymer Capacitors 

Test Inductors Characteristics (Coils and Transformers) 

Test the Characteristics of a Tantalum Capacitor 

Drivers, Firmware, Software

Firmware
V3.11
Translate »