fbpx

DMM STATION MR8990+MR8741/MR8740

Home/Benchtop Digital Multimeters/DMM STATION MR8990+MR8741/MR8740

DMM STATION MR8990+MR8741/MR8740

Measure Minute Changes in Voltage at a High Level of Precision across 54 Channels at the Same Time

SKU: MR8990+MR8741/MR8740 Category:

Model No. (Order Code)

MR8740 Max. 54ch, 864MW memory, main unit only
MR8741 Max. 16ch, 256MW memory, main unit only
MR8990 For DMM Station, MR8741/MR8827 or other

Note: Instrument requires input units and other dedicated options. Input cords not included. The MR8990 cannot operate alone.

LAN
USB 2.0
CE

 

Description

The MR8740 and MR8741 are rack-mountable data acquisition systems that deliver high-speed, multi-channel measurements over maximum of 32+22 channels. The MR8990 DVM unit is a 2-channel input unit for the MR8740/MR8741 for measuring minute fluctuations in output from sensors in automobiles and other equipment and voltage fluctuations in devices such as batteries at high levels of precision and resolution.

Key Features
• Use the new DVM Unit MR8990 to measure DC voltages on 2 channels (for use with the Memory HiCorder MR8741/8740 only)
• High-precision measurement for applications such as investigating minute voltage fluctuations in sensor output
• The MR8741 (MR8740) can save data from 16 (54) Digital Voltmeter Units at once. (DCV measurement only)
• Unlike standard multi-channel scan-type loggers, these instruments can perform simultaneous sampling
• High accuracy of ±0.01 % and super-high 1.2 million-count resolution
• High-speed sampling at 500 samples/s
• Isolated input
(channel-to-channel and channel-to-chassis: max. rated voltag to earth of 300 V AC/DC)

DVM Unit MR8990 Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)

Measurement functions Install into Memory HiCorder MR8740/8741 for use; 2 channels of DC voltage measurement
Measurement ranges (20 div. f.s.) 100 mV range (5 mV/div.): -120.0000 mV to 120.0000mV, 0.1 μV resolution
to
500 V range (50 V/div.): -500.000 V to 500.000 V, 1 mV resolution, 5 ranges
Measurement accuracy Basic accuracy: ±0.01% rdg. ±0.0025% f.s.
Max. allowable input 500 V DC (upper limit voltage that can be applied between input terminals without damage)
Max. rated voltage to earth 300 V AC/DC (input and instrument are isolated; upper limit voltage that can be applied between input channels or between input channels and chassis without damage)
Max. sampling rate 2 ms (500 samples/s)

Main Unit MR8740/8741 Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)

  MR8740 MR8741
Number of channels Block I: 16 analog units]
From 32 analog + 8 standard logic
[Block I: 13 analog units + 3 logic units]
26 analog + 56 logic (8 standard logic + 48 logic unit)
[Block II: 11 analog units]
From 22 analog + 8 standard logic
[Block II: 8 analog units + 3 logic units]
16 analog + 56 logic (8 standard logic + 48 logic unit)
*Instrument consists of two blocks, Block I and Block II
*Block I and Block II start measurement simultaneously by means of trigger synchronization (internal setting)
[8 analog units]
From 16 analog + 16 standard logic
[5 analog units + 3 logic units]
10 analog + 64 logic (16 standard logic + 48 logic unit)
  *Analog unit channels are isolated from each other and from the recorder. Logic unit channels and standard logic terminal channels share a common GND with the recorder.
Memory capacity 16 MW/ch (fixed), total of 864 MW installed 16 MW/ch (fixed), total of 256 MW installed
Removable storage USB memory (2.0)
Display None (1 digital DVI terminal per block, 800 × 600 dots) None (1 digital DVI terminal, 800 × 600 dots)
External interfaces [LAN] 100Base-TX (DHCP and DNS support, FTP server, HTTP server)
[USB] USB 2.0 Series A receptacle × 2 (mouse operation)
Power supply 100 to 240 V AC, 50/60 Hz (250 VA max.) 100 to 240 V AC, 50/60 Hz (120 VA max.)
Dimensions and mass 426 mm (16.77 in)W × 177 mm (6.97 in)H × 505 mm (19.88 in)D, 10.8 kg (3809.5 oz) (main unit only) 350 mm (13.78 in)W × 160 mm (6.30 in)H × 320 mm (12.60 in)D, 5.4 kg (190.5 oz) (main unit only)
Accessories Instruction manual ×1, Application disk (Wave viewer Wv, Communication commands table) ×1, Power cord ×1

Catalogs

Digital Multi-Module (DMM) Station MR8990+MR8741/MR8740

Options

Input cable (G)

* For the MR8990 *Voltage is limited to the specifications of the input modules in use.

 

TEST LEAD L2200

70 cm (2.30ft) length, detachable large alligator clips or needle tips are bundled, CAT IV 600V, CAT III 1000V

Input modules

*Input cords are not included. Please purchase them separately. *When using 9709 with Current Unit 8971, a total of 7 current probes can be used.

 

ANALOG UNIT 8966

2 ch, Voltage input, DC to 5 MHz bandwidth

DIGITAL VOLTMETER UNIT MR8990

• 2 ch, high-precision DC V, 0.1 μV resolution, high-speed sampling 500 times/s

LOGIC UNIT 8973

4 terminals, 16 ch

DC/RMS UNIT 8972

2 ch, voltage/DC to 400 kHz, RMS rectifier, DC and 30 to 100 kHz bandwidth

CURRENT UNIT 8971

2 ch, for measuring current using dedicated current sensors, bundled two Conversion cable 9318

FREQ UNIT 8970

2 ch, for measurement of frequency, rpm, pulse, etc.

STRAIN UNIT 8969

2 ch, strain gauge type converter amp *Includes Conversion Cable 9769

HIGH RESOLUTION UNIT 8968

2 ch, voltage input, DC to 100 kHz bandwidth

TEMP UNIT 8967

2 ch, thermocouple temperature input

Logic signal measurement

* Only the small terminal types can be used. * The 9323 is not required for the small-terminal types 9327, 9320-01, 9321-01 and MR9321-01.

 

CONVERSION CABLE 9323

• Used for connecting the 9320/9321/MR9321 and the 9324 to the Memory HiCorder with small logic terminal models

LOGIC PROBE MR9321,MR9321-01

• 4 isolated channels • ON/OFF detection of AC/DC voltage • Large terminal type

LOGIC PROBE 9320-01,9320

• 4 channels for contact voltage signals • 500ns response • Miniature terminal type

LOGIC PROBE 9327

• 4 channels for contact voltage signals • High-speed 100ns response

PC Software

 

LAN COMMUNICATOR 9333

• For LAN communication with the MR8740/8741, MR8847 series, 8826 • For data collection and remote control

WAVE PROCESSOR 9335

• Convert data, print and display waveforms

iPad App for Memory HiCorder HMR Terminal

• For Memory HiCorder • (Exclusively for Apple Inc. iPad) Free download from the App Store

There are no drivers, firmware or software available for this product.