fbpx

DC SIGNAL SOURCE SS7012

Home/Signal Generators/DC SIGNAL SOURCE SS7012

DC SIGNAL SOURCE SS7012

DC Voltage and Current Signal Generator and Tester for Routine Maintenance of Standard Devices

SKU: SS7012 Category:

Model No. (Order Code)

SS7012

Note: Use of the AC Adapter and /or rechargeable batteries and dedicated charger is recommended

CE
USB 1.1

 

Description

The Hioki SS7012 is a compact DC signal source and calibrator that is used to perform maintenance or loop tests of instrumentation systems and can be operated from a computer via a USB cable. It can also be used to calibrate thermometers and measure DC voltage and DC current.

 

 

Key Features

• Improve stability and reduce calibration costs compared with the previous HIOKI model
• For instrumentation systems (4 - 20 mA) and loop testing
• Check temperature control equipment and electric distribution
• 8 types of thermocouples to test thermoelectric power generation
• Ideal for electrical device evaluating and routine maintenance of production equipment such as calibrators
• Use the max. 25 mA DC sink as an electric load

 

 

Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)[Generation functions]

Circuit method Bipolar sink and source
Constant voltage 2.5 V: 0 to ±2.5000 V (±0.03 % of setting ±300 μV, 100 μV resolution)
25 V: 0 to ±25.000 V (±0.03 % of setting ±3 mV, 1 mV resolution)
Constant current 25 mA: 0 to ±25.000 mA (±0.03 % of setting ±3 μA, 1 μA resolution)
Thermoelectric power generation K: at TC: 0 ˚C, -174.0 to 1372.0 ˚C (±0.05 % of setting ±0.5 ˚C, 0.1 ˚C resolution), Other types: E, J, T, R, S, B, N selectable
Thermoelectric power generation K: at TC: RJ, -174.0 to 1372.0 ˚C (±0.05 % of setting ±1.0 ˚C, 0.1 ˚C resolution), Other types: E, J, T, R, S, B, N selectable
Standard resistance (Rs) 100 Ω (±0.2 Ω)
Automatic generation Number of memory steps: 20, Interval time: 1 to 99 sec (at CV, CC, TC mode)

[Measurement functions]

Voltage 2.5 V: 0 to ±2.8000 V (±0.03 % rdg. ±300 μV, 100 μV resolution, 1 MΩ input resistance)
25 V: 0 to ±28.000 V (±0.03 % rdg. ±3 mV, 1 mV resolution, 1 MΩ input resistance)
Current 25 mA: 0 to ±28.000 mA (±0.03 % rdg. ±3 μA, 1 μA resolution, smaller than 30 Ω input resistance)
Temperature -25.0 to 80.0 ˚C (±0.5 ˚C at 23 ±5 ˚C, 0.1 ˚C resolution, use with the RJ sensor 9184)
Sampling rate Approx. 1.67 times/sec

[General functions]

Additional functions Zero adjustment, Overflow display, USB communication, Monitor
Power supply AC adapter 9445-02/03 (100 to 240 V AC 50/60 Hz, 9 VA),
Ni-MH battery HR6 × 4, 6 VA, (fully charged 2500 mAh Ni-MH batteries: 170 minutes continuous use), or LR6 (AA) alkaline battery × 4, 6 VA
Dimensions and mass 104 mm (4.09 in) W × 180 mm (7.09 in) H × 58 mm (2.28 in) D, 660 g (23.3 oz) (including LR6 × 4 batteries)
Accessories Input cord 9168 ×1, Test lead L9170-10 ×1, Fuse ×1, LR6 (AA) alkaline battery ×4, Instruction manual ×1

Catalogs

DC SIGNAL SOURCE SS7012

Declaration of Conformity

DC SIGNAL SOURCE SS7012 [100KB]

Options

Cables

 

INPUT CORD 9168

70 cm (2.30 ft) length

Input Probes

*L9170-10 is a bundled accessory. *Requires the 9704 to connect a Clamp-on probe

 

TEST LEAD L9170-10

70 cm (2.30 ft) length

Leak Current

*For commercial power lines, 50/60 Hz

 

AC ADAPTER 9445-02

For USA, 100 to 240 V AC, 9 V/ 1 A

Options

 

TEMPERATURE PROBE 9184

For reference contact compensation

CARRYING CASE 9380

For storing the main body only, soft type

COMMUNICATION PACKAGE SS9000

USB cable, USB driver software included

Other options

 

CARRYING CASE 9782

Includes compartment for options, resin-coated