CLAMP ON POWER LOGGER PW3365

Home/Power Quality Analyzers Power Loggers/CLAMP ON POWER LOGGER PW3365

CLAMP ON POWER LOGGER PW3365

The World’s First Non-metallic Contact Power Logger

SKU: PW3365 Category:

Model No. (Order Code)

PW3365-20 main unit only

Note: Clamp On Power Logger PW3365 by itself does not support current and power measurements. Current and power measurements require clamp on sensors, sold separately. Use only HIOKI SD cards guaranteed to work for saving measurement data (options, sold separately).

Good Design
LAN
USB 2.0
CE
TrueRMS
SD

 

Description

Hioki Clamp On Power Meters are multi-channel power measuring devices utilizing clamp sensor input to accurately and safely measure power on single-phase to three-phase lines. The PW3365 power logger takes safety and convenience one step further by being the world’s first non-metallic contact power meter that utilizes completely covered voltage clips that can be attached to any part of a cable or busbar. Customers can now monitor power demand and other power parameters to aid in energy audits and validate energy saving measures without risk of short-circuit accidents, power interruptions, or bodily injury due to electrocutions.

Key Features
• The PW3365’s dedicated voltage sensor delivers the world’s first no-metal-contact measurement.
• Supports single to three-phase, 4-wire circuits
• Measure between 90V to 520V
• Slim, compact design that can be placed anywhere
• Store months of data on SD cards
• The QUICK SET function guides you in making the right connections

Award

• German Design Award Special 2016 (*For Voltage Sensor PW9020)
• 2015 The Nikkan Kogyo Shimbun MACHINE DESIGN AWARD Distinctive Merit Award (* For PW3365)

 

 

Product Video

 

Safely and easily measure power without the need to shut off the circuit breaker first with a clamp-on power logger

Although technicians had to connect instruments to metal terminals in order to measure voltage when measuring power in the past, Hioki’s newly developed no-metal-contact voltage sensor makes it possible to measure voltage simply by clamping the sensor around an insulated wire. This approach completely eliminates the risk of short-circuits since metal never comes into contact with live components, and it simplifies the sensor attachment process even when terminals are covered since the sensor can be simply clipped around the cable without removing the cover.

 

 

Graphical, easy-to-understand guidance on how to connect the clamp-on power logger

The PW3365’s Quick Setup feature guides you through the process of setting up the instrument for measurement, right up to starting measurement, to make even 3-phase power measurement a breeze. Since any mistaken connections will trigger a FAIL message, the feature also helps prevent measurement mistakes.

 

 

Display clamp-on power logger measurement results as a graph so you can review them at a glance

The PW3365 displays recorded measured values as a graph for convenient use in power management. In addition to instantaneous measured values, you can review maximum, minimum, and average values by moving the cursor on the demand and trend graph displays.

 

 

Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 6 months)

Measurement line & number of circuits 50/60 Hz, Single phase 2 wires (1/2/3 circuits), Single phase 3 wires (1 circuit), Three phases 3 wires (1 circuit), Three phases 4 wires (1 circuit), Current only: 1 to 3 channels
Measurement items Voltage RMS, current RMS, voltage fundamental wave value, current fundamental wave value, voltage fundamental wave phase angle, current fundamental wave phase angle, frequency (U1), voltage waveform peak (absolute value), current waveform peak (absolute value), active power, reactive power, apparent power, power factor (with lag/lead display) or displacement power factor (with lag/lead display), active energy (consumption, regeneration), reactive energy (lag, lead), energy cost display, active power demand quantity (consumption, regeneration), reactive power demand quantity (lag, lead), active power demand value (consumption, regeneration), reactive power demand value (lag, lead), power factor demand
Voltage ranges 400 V AC (Effective measurement range: 90.0 V to 520.0 V)
Current ranges 500.00 mA to 5.0000 kA AC (depends on current sensor in use),
50.000 mA to 5.0000 A AC (Leak clamp on sensor only)
Power ranges 200.00 W to 6.0000 MW (depends on voltage/current combination and measured line type)
Basic accuracy Voltage : ±1.5% rdg. ±0.2% f.s(combined accuracy with PW3365-20 + PW9020)
Current : ±0.3% rdg. ±0.1% f.s. + clamp sensor accuracy
Active power : ±2.0% rdg. ±0.3% f.s. + clamp sensor accuracy (at power factor = 1)
Display update rate 0.5 sec (except when accessing SD card or internal memory, or during LAN/USB communication)
Save destination SD Memory card, or internal memory at real time
Data save interval 1 sec to 30 sec, 1 minute to 60 minutes, 14 selections
Save items Measurement value save: Average only / Average, Maximum, Minimum value
Screen copy: BMP form (saved every 5 min. at minimum interval time)
Waveform save: Binary waveform data
Interfaces SD memory card
HTTP server function, remote settings via communication program, data download
USB 2.0: When connected to a PC, the SD Card and internal memory are recognized as removable storage devices, remote settings via communication program, data download
Pulse output: proportional to active power consumption when measuring integral power consumption, Isolated open-collector signal
Functions Connection check, Quick Set navigation guide, clock
Power supply AC adapter Z1008: (100 to 240 V AC, 50/60 Hz), 45 VA (including AC adapter)
Battery pack 9459: (DC 7.2 V, 3 VA, charging time 6 hr 10 m), 5 hours of continuous use (with back light off)
Dimensions and mass 180 mm (7.09 in)W × 100 mm (3.94 in)H × 48 mm (1.89 in)D, 540 g (19 oz) without PW9002
180 mm (7.09 in)W × 100 mm (3.94 in)H × 68 mm (2.68 in)D, 820 g (28.9 oz) with PW9002
Accessories Safety Voltage Sensor PW9020 ×1 set, AC adapter Z1008 ×1, USB cable ×1, Instruction manual ×1, Measurement guide ×1, Color spiral tubes ×1 set: red, yellow, blue/four each, Spiral tubes for grouping clamp sensor cords ×10

Catalogs

CLAMP ON POWER LOGGER PW3365

Manuals

CLAMP ON POWER LOGGER PW3365

User Guides

MEASUREMENT GUIDE CLAMP ON POWER LOGGER PW3365

Technical Notes

Clamp On Power Logger PW3365/Safety Voltage Sensor PW9020

Declaration of Conformity

CLAMP ON POWER LOGGER PW3365-10,PW3365-20,PW3365-30 [101KB]

Options

500 A to 5000 A

*For commercial power lines, 50/60 Hz

 

AC FLEXIBLE CURRENT SENSOR CT9667

• 10 Hz to 20 kHz (±3dB) • 5000 A/ 500 A AC rated input • 500 mV/f.s. output • φ 100 mm (3.94 in) core dia. to φ 254 mm (10.00 in), 3 loop diameters

Adapter

 

CLAMP ON ADAPTER 9290-10

• Primary 1000A, secondary 100A (1/10 ratio) output • Superior phase angle characteristics for power

Current input

 

CLAMP ON SENSOR 9694

• 40Hz to 5kHz • Phase: 45Hz to 5kHz • 5 A AC rated input • 10 mV AC / A output • φ 15 mm (0.59 in) core dia.

CLAMP ON SENSOR 9695-03

• 40 Hz to 5 kHz • Phase: 45 Hz to 5 kHz • 100A AC rated input • 1mV AC/A output • φ 15 mm (0.59 in) core dia.

CLAMP ON SENSOR 9661

• 40Hz to 5kHz • Phase: 45Hz to 5kHz • 500A AC rated input • 1mV AC/A output • φ 46 mm (1.81 in) core dia.

CLAMP ON SENSOR 9660

• 40Hz to 5kHz • Phase: 45Hz to 5kHz • 100 A AC rated input • 1 mV AC / A output • φ 15 mm (0.59 in) core dia.

Current sensors (AC leak)

 

CLAMP ON LEAK SENSOR 9657-10

• 40 Hz to 5 kHz • Rated 10 A AC • 100 mV AC/A output • φ 40 mm (1.57 in) core dia.

CLAMP ON LEAK SENSOR 9675

• 40 Hz to 5 kHz • Rated 10 A AC • 100 mV AC/A output • φ 30 mm (1.18 in) core dia.

Current sensors (AC load)

 

CLAMP ON SENSOR 9669

• 40Hz to 5kHz • Phase: 45Hz to 5kHz • 1000A AC rated input • 0.5mV AC/A output • φ55 mm (2.17 in) core dia.

CLAMP ON SENSOR 9695-02

• 40 Hz to 5 kHz • Phase: 45 Hz to 5 kHz • 50A AC rated input • 10mV AC /A output • φ 15 mm (0.59 in) core dia.

CONNECTION CABLE 9219

Connect with the 9695-02/ -03, Output BNC terminal, 3m (9.84ft) length

Input cable (D)

* Voltage to ground is within this product’s specifications, separate power source is also required.

 

AC ADAPTER Z1008

100 to 240V AC

Other options

 

POWER LOGGER VIEWER SF1001

• Easy graphical processing of measurement data saved with the PW3360/3365 series, 3169 series on a PC

CARRYING CASE C1005

For PW3360/3365 series, for storing options

CARRYING CASE C1008

For PW3365, for storing Current sensor ×3, Voltage sensor ×4 pieces

PC Software

 

LAN CABLE 9642

Straight Ethernet cable, supplied with straight to cross conversion adapter, 5 m (16.41 ft) length

Power supply

*Not necessary when using Current Unit 8971.

 

BATTERY PACK 9459

NiMH, Charges while installed in the main unit

BATTERY SET PW9002

Battery case and Battery Pack 9459 Set

Storage media

*The CF card includes a PC card adapter. PC Card Precaution Use only PC Cards sold by HIOKI. Compatibility and performance are not guaranteed for PC cards made by other manufacturers. You may be unable to read from or save data to such cards.

 

SD MEMORY CARD 2GB Z4001

2 GB capacity

Voltage measurement

*PW9020 ×4 pieces are bundled, additional single sensors also available

 

SAFETY VOLTAGE SENSOR PW9020

For PW3365, 3 m (9.84 ft) length