fbpx

CHEMICAL IMPEDANCE ANALYZER IM3590

Home/LCR Meters Impedance Analyzers/CHEMICAL IMPEDANCE ANALYZER IM3590
Exclusive Academic Offer

CHEMICAL IMPEDANCE ANALYZER IM3590

For R & D applications of Electrochemical Components and Materials, Batteries, and EDLCs

SKU: IM3590 Category:

Model No. (Order Code)

IM3590 For electrochemical components

Note: This product is not supplied with measurement probes or test fixtures. Please select and purchase the measurement probe or test fixture options appropriate for your application separately. For an RS-232C connection: A crossover cable for interconnection can be used. You can use the RS-232C Cable 9637 without hardware flow control.

LAN
USB 2.0
CE
GPIB
RS232C

 

Description

Hioki LCR Meters and Impedance Analyzers range from 1mHz to 3GHz devices to suit a wide range of applications in the testing of electronic components.. The IM3590 impedance analyzer is an advanced component tester especially suited to electrochemical impedance measurements and includes a variety of graphing functions that are needed for battery and chemical material testing.

Key Features
• Broad 1 mHz to 200 kHz signal source range supports measurements of ion behavior and solution resistance
• Continuous measuring and high-speed testing of LCR and sweep measurements with a single instrument
• Measure internal impedance of batteries with no load
• Perform high-speed sweep measurements in as little as 2 ms
• Basic accuracy of ±0.05% is ideal for applications from component testing to R&D
• Measure LCR impedance for Cole-Cole plots and equivalent-circuit analyses of electro-chemical components and materials

 

 

Hioki IM3590 Chemical Impedance Analyzer: Cole-Cole plot generation, equivalent circuit analysis, and other impedance measurement capabilities

In addition to measuring electrochemical components and materials, batteries, and electrical double-layer capacitors, the Hioki IM3590 can generate Cole-Cole plots and perform equivalent circuit analysis.

Key applications:
Analyze the internal phenomena in batteries, for example charge transfer resistivity at the electrode/electrolyte interface and the mass transfer process in electrolytes

 

 

Hioki IM3590 Chemical Impedance Analyzer:
Battery internal resistance measurement and battery measurement function

The Hioki IM3590 can measure a battery’s internal resistance in the no-load state by automatically measuring the battery voltage and generating the same DC voltage.
• Measurement range: 10 mΩ to 10 Ω
• Battery voltage: 5 V or less

For more information, please visit https://www.hioki.com/en/products/detail/?product_key=5749.

 

 

Hioki IM3590 Chemical Impedance Analyzer:
Ascertain the frequency characteristics of electronic components, piezoelectric elements, and resonant elements

The Hioki IM3590 makes it easy to ascertain characteristics of electronic components with frequency sweep measurement (through up to 801 points), frequency characteristic measurement, and Cole-Cole plot display functionality. The impedance analyzer can also sweep through multiple signal levels (voltage and current) and DC bias voltages.

 

 

Hioki IM3590 Chemical Impedance Analyzer:
Ascertain changes in the behavior of electronic components over time with time interval measurement

Thanks to a time interval measurement function with up to 801 points, the Hioki IM3590 can generate a graph illustrating how the characteristics of an electronic component can change over time in response to changes in environmental conditions such as temperature.

 

 

Application information

Download the sample application and view the Communications Command User Manual.

 

Click here for the LCR application.

Accuracy calculation information

Calculate accuracy by simply entering a numerical value.

 

Click here to calculate accuracy.

Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)

Measurement modes LCR mode, Continuous measurement mode (LCR mode / Analyzer mode), Analyzer mode (Sweeps with measurement frequency and measurement level, temperature characteristics, equivalent circuit analysis)
Measurement parameters Z, Y, θ, Rs (ESR), Rp, Rdc (DC resistance), X, G, B, Cs, Cp, Ls, Lp,
D (tanδ), Q, T, σ (conductivity), ε (dielectric constant)
Measurement range 100 mΩ to 100 MΩ, 10 ranges (All parameters are determined according to Z)
Display range Z, Y, Rs, Rp, Rdc, X, G, B, Ls, Lp, Cs, Cp, σ, ε :
±(0.00000 [unit] to 9.99999G [unit], Absolute value display for Z and Y only
θ : ±(0.000° to 180.000°), D : ±(0.00000 to 9.99999)
Q : ±(0.00 to 99999.9), Δ % : ±(0.0000% to 999.999%)
T : -10.0°C to 99.9°C
σ, ε :±(0.00000f [unit] to 999.999G [unit]
Basic accuracy Z: ±0.05% rdg. θ: ±0.03°
Measurement frequency 1 mHz to 200 kHz (5 digits setting resolution, minimum resolution 1 mHz)
Measurement signal level Normal mode:
V mode/CV mode: 5 mV to 5 Vrms, 1 mVrms steps
CC mode: 10 μA to 50 mArms, 10 μArms steps
Low impedance high accuracy mode:
V mode/CV mode: 5 mV to 2.5 Vrms, 1 mVrms steps
CC mode:10 μA to 100 mArms, 10 μArms steps
Output impedance Normal mode: 100 Ω, Low impedance high accuracy mode: 25 Ω
Display 5.7-inch color TFT, display can be set to ON/OFF
Measurement time 2 ms (1 kHz, FAST, display OFF, representative value)
Functions DC bias measurement, DC resistance temperature compensation (converted reference temperature is displayed), Temperature measurement, Battery mesurement (Automatic DC biasing system), Comparator, BIN measurement (classification), Panel loading/saving, Memory function
Interfaces EXT I/O (Handler), USB communication (high-speed), USB memory
Optional: Choose 1 from RS-232C, GP-IB, or LAN
Power supply 100 to 240 V AC, 50/60 Hz, 50 VA max.
Dimensions and mass 330 mm (12.99 in) W × 119 mm (4.69 in) H × 168 mm (6.61 in) D, 3.1 kg (109.3 oz)
Accessories Power cord ×1, Instruction manual ×1, CD-R (Communication instruction manual and sample software [Communications control, accuracy calculation, and screen capture functionality] ) ×1

Catalogs

Catalog: LCR METER Series

CHEMICAL IMPEDANCE ANALYZER IM3590

SMD TEST FIXTURE IM9110

Declaration of Conformity

LCR METER IM3533,IM3533-01 CHEMICAL IMPEDANCE ANALYZER IM3590 [121KB]

Options

PC communication

 

GP-IB INTERFACE Z3000

LAN INTERFACE Z3002

RS-232C INTERFACE Z3001

GP-IB CONNECTOR CABLE 9151-02

2 m (6.56 ft) length

Probe and Test fixtures

 

SMD TEST FIXTURE 9677

Direct connection type, For measuring SMDs with electrodes on the side; DC to 120 MHz, test sample dimensions: 3.5 mm ±0.5 mm (0.14 in ±0.02 in)

SMD TEST FIXTURE 9699

Direct connection type, For measuring SMDs with electrodes on the bottom; DC to 120 MHz, test sample dimensions: 1.0 mm (0.04 in) to 4.0 mm (0.16 in) wide, max. 1.5 mm (0.06 in) high

CONTACT TIPS IM9901

To replace the tip on the L2001, regular size, bundled with the L2001

CONTACT TIPS IM9902

To replace the tip on the L2001, small size

4-TERMINAL PROBE L2000

Cable length 1 m (3.28 ft), DC to 8 MHz, impedance characteristics of 50 Ω, 4-terminal pair configuration, measurable conductor diameter: ø0.3 (0.01 in) to 5 mm (0.20 in)

PINCHER PROBE L2001

Cable length 73 cm (2.40 ft), DC to 8 MHz, impedance characteristics of 50 Ω, 4-terminal pair configuration, tip electrode spacing: 0.3 (0.01 in) to 6 mm (0.24 in)

SMD TEST FIXTURE IM9110

• Direct connection two-terminal measurement type • DC to 1 MHz • Measurable sample sizes: 008004 (EIA)

4-TERMINAL PROBE 9500-10

Cable length 1 m (3.28 ft), DC to 200 kHz, impedance characteristics of 50 Ω, measurable conductor diameter: φ0.3 mm (0.01 in) to 2 mm (0.08 in)

DC BIAS CURRENT UNIT 9269-10

Direct connection type, 40 Hz to 2 MHz, maximum applied current of DC 2 A

SMD TEST FIXTURE IM9100

• Direct connection type • SMDs with electrodes on the bottom • DC to 8MHz • Measurable sample sizes: 01005 to 0402 (EIA)

4-TERMINAL PROBE 9140-10

Cable length 1 m (3.28 ft), DC to 200 kHz, impedance characteristics of 50 Ω, 4-terminal pair configuration, measurable conductor diameter: ø0.3 (0.01 in) to 5 mm (0.20 in)

TEST FIXTURE 9261-10

Cable length 1 m (3.28 ft), DC to 8 MHz, impedance characteristics of 50 Ω, 4-terminal pair configuration, measurable conductor diameter: ø0.3 (0.01 in) to 1.5 mm (0.06 in)

TEST FIXTURE 9262

Direct connection type, DC to 8 MHz, measurable conductor diameter: ø0.3 (0.01 in) to 2 mm (0.08 in)

SMD TEST FIXTURE 9263

Direct connection type, DC to 8 MHz, Test sample dimensions:1 mm (0.04 in) to 10 mm (0.39 in)

DC BIAS VOLTAGE UNIT 9268-10

Direct connection type, 40 Hz to 8 MHz, maximum applied voltage of DC ±40 V

Temperature probe

 

SHEATH TYPE TEMPERATURE PROBE 9478

Pt100, Tip dia. φ2.3 mm (0.09 in), Cord length 1 m (3.28 ft), Waterproof construction

Drivers, Firmware, Software

Translate »