fbpx

AUTOMATIC INSULATION / WITHSTANDING HiTESTER 3153

Home/Electrical Safety Testers Hipot Testers/AUTOMATIC INSULATION / WITHSTANDING HiTESTER 3153

AUTOMATIC INSULATION / WITHSTANDING HiTESTER 3153

0.2 kV to 5 kV AC Programmable and Fully Remote Controllable Automatic Hipot Tester

Model No. (Order Code)

3153
CE
GPIB
RS232C

 

Description

The Hioki electrical safety testers are designed for insulation resistance and voltage withstand testing of electrical devices and components according to various safety standards. The 3153 is an automatic insulation and AC/DC voltage withstanding tester that fully supports automated testing.

Key Features
• Programmable insulation (50 to 1,200 V DC) and dielectric strength (AC/DC) testing
• Program up to 32 files of test types, test points (50 steps), and measurement settings
• Optional scanner for multipoint automatic testing
• Uses the PWM method to generate accurate test voltages that do not depend on the supply voltage
• Ramp timer function for increasing or decreasing the applied voltage during dielectric strength testing at user-specified times

 

 

Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)

Functions Program up to 32 files of 50 step test settings.
10 sets each of dielectric strength and insulation test settings, hold, buzzer
Monitor functions Output voltage, detected current, measured resistance, Refresh rate: 2 times/s
Power supply 100 to 120 V, 200 to 240 V AC, (50/60 Hz), 1000 VA max.
Dimensions and mass 320 mm (12.60 in) W × 155 mm (6.10 in) H × 480 mm (18.9 in) D, 18 kg (634.9 oz)
Accessories H.V. Test Lead 9615 (high voltage side and return, 1 each) ×1, Power cord ×1, Instruction manual ×1, Spare fuse ×1

[Withstanding test]

Testing voltage AC/DC 0.2 kV to 5.00 kV AC, 500 VA (max. 30 minutes), 0.2 kV to 5.00 kV DC, 50 VA (continuance)
Voltage setting Digital setting (0.01 kV setting resolution)
Waveform/Frequency Sine wave (5% or less distortion, unloaded), 50/60 Hz selectable
Current measurement 0.01 mA to 100.0 mA, Average rectified display (Digital)
Measurement range 10 mA (0.01 mA resolution), 100 mA (0.1 mA resolution)
Voltmeter Digital: accuracy ±1.5 % f.s. (f.s.=5.00 kV) (Average rectified display)
Decision method Window comparison (digital settings)

[Insulation test]

Rated testing voltage 50 to 1,200 V DC (in 1 V steps)
Rated testing current 1 mA, Short-circuit current: 200 mA or less
Measurement range/accuracy 0.10 to 9999 MΩ, 4 ranges, ± 4 % rdg. (representative values for 0.5 MΩ to 1,000 MΩ)
Decision method Window comparison (digital settings)

[Timer]*Test times may differ from set timer times depending on the load.

Setting range 0.3 to 999 s
Ramp/delay Testing voltage ramp-up, or down, Insulation test delay: 0.1 to 99.9 s

Catalogs

INSULATION / WITHSTANDING Test Instrument series 3153/3159/ST5520

User Guides

Introducing the safety standards, testing methods, and appropriate test instruments for electrical medical equipment

Declaration of Conformity

AUTOMATIC INSULATION/WITHSTANDING HiTESTER 3153 [101KB]

Options

Input/Output cords

*The 9615 is bundled

 

H.V. TEST LEAD 9615

Red, Black each 1, 1.5 m (4.92 ft) length

REMOTE CONTROL BOX (SINGLE) 9613

For Start/Stop control, 1.5m (4.92 ft) cord length

REMOTE CONTROL BOX (DUAL) 9614

For Start/Stop control, 1.5m (4.92 ft) cord length

Other

 

SAFETY TEST DATA MANAGEMENT SOFTWARE 9267

• PC software for controlling electrical safety measuring instruments

HIGH VOLTAGE SCANNER 3930

• Supports remote control • For automatic multipoint testing of insulation / withstand voltage • Use with the 3153's program or with general-purpose logic sequencers

PC communication

 

GP-IB CONNECTOR CABLE 9151-02

2 m (6.56 ft) length

RS-232C CABLE 9637

For the PC, 9 pin - 9 pin, cross, 1.8 m (5.91 ft) length

RS-232C CABLE 9638

For the PC, 9 pins - 25 pins, cross, 1.8m (5.91 ft) length

Comprehensive Testing of Coils and Transformers 

There are no drivers, firmware or software available for this product.

Translate »