Description

Hioki clamp meters are best-in-class measuring devices incorporating Hioki’s expertise in current sensing technology. The CM4373 is a 2000A True RMS clamp meter that features stronger jaws, broader -25℃ to 65℃ operating temperature range and IP54 dustproof and waterproof enclosure to enable professionals to work quickly in tough situations including the development, repair, and maintenance of equipment and devices such as electric vehicles. Additionally, the high-voltage DC measurement capability of up to 1700 V is ideal for the clamp maintenance inspections of electrical and solar power equipment.

CAT IV 600 V, CAT III 1000 V

 

 

Germany iF Design Award CM4371 series

 

Key Features

• Multiple measurement functions such as current, voltage, resistance, frequency, and voltage detection
• Simultaneously measure inrush current in RMS and crest values
• Damage-resistant jaws (current sensor) provide even more years of reliable use.
• Expanded -25 °C to 65 °C operating temperature range
• IP54 dustproof and waterproof enclosure
*Jaws (current sensor portion): IP50
• Automatic AC/DC function helps boost work efficiency
• Remain alert to hazards with a red backlight and beeping tone
• Measure DC voltages of up to 1700 V

 

 

How to Use the Hioki CM4370 Series Clamp Meters
Current Measurement Function:

Learn how to effectively use the current measurement function with this short video.

 

 

How to Use the Hioki CM4370 Series Clamp Meters
Auto Hold Function:

The Auto Hold feature is perfect in situations where the display is hard to read because the clamped wires are in hard to reach locations. With Auto Hold, measured results automatically freeze on the display until the next measurement starts, making testing and record taking a snap.

 

 

How to Use the Hioki CM4370 Series Clamp Meters
Max/Min/AVG/Peak Function:

Watch this video to learn how to capture the maximum, minimum, average and peak values of a current signal, available when the AUTO AC/DC mode is not in use.

 

 

How to Use the Hioki CM4370 Series Clamp Meters
Simultaneous Display of DC Current and DC Voltage:

The CM4370 Series can measure both DC current and DC voltage with a single device at the same time, making it ideal for automotive battery testing and inspection and maintenance of solar panels.

 

 

How to Use the Hioki CM4370 Series Clamp Meters
Inrush Measurement Function:

Accurately measure the startup or inrush current of motors and equipment. The CM4370 series is engineered to detect the full startup current period and then identify the RMS waveform as well as the highest waveform peak.

 

 

How to Use the Hioki CM4370 Series Clamp Meters
Voltage Measurement Function:

The DMM function of the AC/DC clamp meter is advanced enough to measure up to 1700V AC/DC. Watch this video to learn more.

 

 

How to Use the Hioki CM4370 Series Clamp Meters
Continuity Check Function:

The DMM function of the AC/DC clamp meter also provides a continuity check function. Easily detect short-circuits with the clear buzzer and red LED.

 

 

How to Use the Hioki CM4370 Series Clamp Meters
AC Voltage Detection Function:

The tip of the current sensor of the CM4370 Series can also detect live voltages, eliminating the need for you to use a separate voltage detector. Energized lines are identified with a loud buzzer and red LED on the clamp meter.

 

 

Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)

DC Current 600.0 A/2000 A, Basic accuracy: ±1.3% rdg. ±0.3 A (600 A range)
AC Current 600.0 A/2000 A (10 Hz to 1 kHz, True RMS), Basic accuracy: ±1.3% rdg. ±0.3 A (at 600 A)
Crest factor 600.0 A range: 3 or less,
2000 A range: 2.84 or less
DC+AC Current 600.0 A/2000 A (10 Hz to 1 kHz, True RMS), Basic accuracy: ±1.3% rdg. ±1.3 A (at 600 A)
DC Voltage 600.0 mV to 1500 V, 5 ranges, Basic accuracy: ±0.5% rdg. ±3 dgt.
AC Voltage 6.000 V to 1000 V, 4 ranges (15 Hz to 1 kHz, True RMS), Basic accuracy: ±0.9% rdg. ±3 dgt.
DC+AC Voltage 6.000 V to 1000 V, 4 ranges, Basic accuracy: ±1.0% rdg. ±7 dgt.
Resistance 600.0 Ω to 600.0 kΩ, 4 ranges, Basic accuracy: ±0.7% rdg. ±5 dgt.
Electrostatic capacity 1.000 μF to 1000 μF, 4 ranges, Basic accuracy: ±1.9% rdg. ±5 dgt.
Frequency 9.999 Hz to 999.9 Hz, Basic accuracy: ±0.1% rdg. ±1 dgt.
Temperature (K) -40.0 to 400.0 ˚C, add temperature probe accuracy to basic accuracy of ±0.5% rdg. ±3.0 ˚C
Voltage detection Hi: 40 V to 600 V AC, Lo: 80 V to 600 V AC, 50/60 Hz
Other functions Automatic AC/DC detection, Plus/Minus judgement function of DC A, DC V, Max/Min/Average/PEAK MAX/ PEAK MIN value display, Filter function, Display value hold, Auto hold, Back light, Auto-power save, Buzzer sounds, Zero-adjustment
Dustproof, waterproof Grip: IP54 (when measuring an insulated conductor only), Jaw (the current sensor portion of the instrument)/ barrier: IP50 *Risk of electric shock from the conductor being measured increases when wet.
Power supply LR03 Alkaline battery ×2, Continuous use 45 hr (Backlight OFF)
Core jaw diameter 92 mm (3.62 in) W×18 mm (0.71 in) D, φ55 mm (2.17 in)
Dimensions and mass 65 mm (2.56 in) W×250 mm (9.84 in) H×35 mm (1.38 in) D mm, 530 g (18.7 oz)
Accessories TEST LEAD L9207-10, CARRYING CASE C0203, LR03 Alkaline battery ×2, Instruction Manual×1

Catalogs

CLAMP ON HiTESTER Series

AC/DC CLAMP METER CM4370 series

Manuals

AC/DC CLAMP METER CM4371,CM4372,CM4373,CM4374 [3MB]

AC/DC CLAMP METER CM4371,CM4372,CM4373,CM4374 [14MB]

AC/DC CLAMP METER CM4371,CM4372,CM4373,CM4374 [4MB]

AC/DC CLAMP METER CM4371,CM4372,CM4373,CM4374 [3MB]

Technical Notes

AC/DC Clamp Meter CM4370 Series

Declaration of Conformity

AC/DC CLAMP METER CM4371,CM4372,CM4373,CM4374 [110KB]

Others

Usable temperature range Max.65°C Max.-25°C

Options

Bundled Accessories

 

CARRYING CASE C0203

Input cable (B)

*Voltage is limited to the specifications of the input modules in use.

 

GRABBER CLIP 9243

Attaches to the tip of the banana plug cable, Red/ Black: 1 each, 196 mm (7.72 in) length, CAT III 1000 V

Input cable (F)

* Voltage input via banana terminals limited by the voltage specifications of the respective input unit.

 

MAGNETIC ADAPTER SET L4937

Attaches to the tip of the banana plug cable, CAT III 1000V

BUS BAR CLIP SET L4936

Attaches to the tip of the banana plug cable, CAT III 600V

ALLIGATOR CLIP SET L4935

Attaches to the tip of the banana plug cable, CAT IV 600V, CAT III 1000V

EXTENSION CABLE SET L4931

Expands the length of the cable with banana plug, 1.5 m (4.92 ft) length

Input cable options

Test Pin Set L4932 is required when using the Small Alligator Clip Set L4934.

 

BREAKER PIN SET L4939

Attaches to the tip of the banana plug cable, CAT III 600V

TEST PIN SET L4938

Attaches to the tip of the banana plug cable, CAT III 600V

SMALL ALLIGATOR CLIP SET L4934

Attaches to the tip of the L4932, L9207-10/DT4911, L9206, CAT III 300V, CAT II 600V

TEST PIN SET L4932

Attaches to the tip of the banana plug cable, CAT IV 600V, CAT III 1000V

Temperature measurement

 

THERMOCOUPLES(K) DT4910

K type, tip exposed, 0.3 mm (0.01 in) diameter, 80 cm (2.62 ft) length, -40 to 260 °C (-40 to 500 °F), tolerance ±2.5 °C

Test leads A

Options for the L9207-10

 

TEST LEAD L9207-10

90 cm (2.95 ft) length

CONTACT PIN SET L4933

Attaches to the tip of the Test Lead L9207-10/DT4911, L9206, 70V DC/ 33V AC

Test leads B

Options for the L4930, Test Pin Set L4932 is required when using the Small Alligator Clip Set L4934.

 

CONNECTION CABLE SET L4930

1.2 m (3.94 ft) length

Simple Method for Evaluating Strings of PV Cells 

There are no drivers, firmware or software available for this product.