fbpx

AC CLAMP POWER METER CM3286

Home/Power Quality Analyzers, Clamp Meters/AC CLAMP POWER METER CM3286

AC CLAMP POWER METER CM3286

Quickly Check Current, Voltage, Power, and Power Factor

Model No. (Order Code)

CM3286
CM3286-01 Built in Bluetooth® wireless technology

Note: *The indicated value for three-phase power is based on the assumption of a balanced condition and sine wave without distortion at 50/60 Hz. Accurate measurement is not possible on an unbalanced or inverter controlled three-phase line. Also, if the phase (zero cross) cannot be detected due to significant waveform distortion, it cannot be measured nor displayed. *The power factor / phase angle are values obtained from the zero cross of the current and voltage. If the phase (zero cross) cannot be detected due to significant waveform distortion, it cannot be measured nor displayed.

CE
Bluetooth
TrueRMS

 

Description

Hioki clamp meters are best in class handheld current and voltage meters for safely and accurately measuring power lines. The CM3286 clamp on power meter can measure voltage, current, power, power factor, phase angle, reactive power or frequency, as well as detect phase sequence on live lines at any desired point of a single-phase circuit or three-phase circuit.

CAT IV 600V, CAT III 1000V
Key Features
• Display four parameters simultaneously
• A handheld power meter that measures from 5 W of power and 60 mA of current
Measure power ranging from 5 W at a low current of 60 mA to 360 kW
• In addition to current, voltage, and power, measure simple integral power consumption and phase sequence
• Features and functions deliver fast and efficient testing
• Hold measured values to send them to a smartphone, quick and easy data recording (CM3286-01 only)

Data can be downloaded to tablets and smartphones using Hioki’s dedicated apps available from the Google Play or App Store. (CM3286-01 only)
Search for “HIOKI” and download the “GENNECT Cross” app.

*Android, Google Play and the Google Play logo are trademarks of Google Inc.
*iOS is a registered trademark of Cisco Technology, Inc. and/or its affiliates in the United States and certain other countries.
*iPhone, iPad, iPad mini, iPad Pro and iPod touch are trademarks of Apple Inc.
*Apple and the Apple logo are trademarks of Apple Inc. App Store is a service mark of Apple Inc.
*Microsoft, Windows, Windows Vista, and Excel are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries.
*Company names and Product names appearing in this catalog are trademarks or registered trademarks of various companies.
*The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by HIOKI E.E. CORPORATION is under license.
*For the latest information about countries and regions where wireless operation is currently supported, please visit the Hioki website.

Broad measurement range

Delivering a broad range of measurements at sites from manufacturing plants to households
Accurately measure power from 5 W at a current as low as 60 mA to 360 kW at a maximum of 600 A (single-phase power measurement)

Measure power in single-phase to balanced three-phase circuits (with estimated values)
(1-phase/ 2-wire, 1-phase/ 3-wire, balanced 3-phase/ 3-wire, and balanced 3-phase/ 4-wire)
*The instrument generates estimated power values when measuring 3-phase circuits

 

 

 

Easy-to-see display

Related parameters and connection locations shown on the display at once (Main parameter×1, Sub-parameter×3)

 

 

Quick and easy data recording (CM3286-01 only)

When you freeze the measured value, it is automatically transferred to a smartphone or tablet, eliminating the need to jot down readings by hand.
You can also create a simple PDF report right there in the field, and save data in CSV format for later editing in Excel.

*Available for Android and iOS devices
*GENNECT Cross (freeware) is required to use instruments with a smartphone or tablet.

 

 

Simple wiring guide

The CM3286 provides a simple on-screen guide indicating how to connect it to a 3-phase circuit.

 

 

Built-in AUTO HOLD function

The clamp meters beep when the measured value stabilizes and then automatically hold the display value.
This is useful when using the instrument in locations where it is difficult to see the display or press the hold button.

 

 

Double warnings with sound and light

When the clamp power meter detects excessively over current or voltage input during a continuity check, it alerts you with a red backlight and beeping tone in order to help prevent accidents.

 

 

Quickly check for unbalance

The CM3286 can measure unbalanced power in a 3-phase/ 3-wire circuit by measuring the single-phase power twice and then automatically adding the results.
(The instrument can also measure 3-phase/4-wire circuits in three separate measurements.)

 

 

Easily check power supply fluctuations

Since it can display maximum (MAX), minimum (MIN), and average (AVG) values, the CM3286 is useful when you need to ascertain the magnitude of fluctuations.
And since it can also measure crest (PEAK) values, you can use it to check fluctuations at the crest value level.

 

 

Support for large-diameter, high-current measurement

The CM3286 can be used with the optional Clamp On Adapter 9290-10 to measure busbars of up to 55 mm in diameter or 80 × 20 mm.
Measure high currents of up to 1000 A AC (or 1500 A for up to 5 min.).

 

 

Accurately detect electricity theft

The CM3286 is ideal for verifying electricity theft since it can measure both AC power and current.

● Meter tampering: Detect by comparing electric meter readings and measurements
Proper operation of electric meters can be confirmed by comparing meter readings and actual values.

● Direct theft: Detect by measuring current
Electricity theft can be detected by measuring current on the power supply side of the illegal connection.

 

 

Electricity theft detection-and-report function (CM3286-01 only)

The instrument’s electricity theft detection-and-report function can be used to quickly and easily make measurements and generate reports (CM3286-01 only).

Simply follow the measurement procedure to take measurements and photographs at four locations and the instrument will automatically generate a report, complete with photos.

Since the report is generated automatically in the field based on captured measurement data, it’s impossible for others to alter the data.

 

 

Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)*1) Phase angle obtained from zero cross of current / voltage. *2) Harmonic levels can be displayed with the GENNECT Cross dedicated application software at a future update. Android support scheduled for fall 2017. iOS support scheduled for 2018.

Measurement line Single-phase, Three-phase (balanced with no distortion)
Measurement items Voltage, Current, Voltage/ current peak, Active/ reactive/ apparent power, Power factor, Phase angle *1, Reactivity, Frequency, Simple Active Energy Consumption (Single-phase) [CM3286-01 only*2] Voltage/ current harmonic levels
AC voltage [Measurement range] 80.0 V to 600.0 V, Single range,
Basic accuracy 45 - 66 Hz: ±0.7% rdg. ±3 dgt.
(Frequency characteristics: 45 to 1 kHz, True RMS)
AC current [Measurement range] 0.060 A to 600.0 A, 3 range, Basic accuracy:
±1.3% rdg. ±3dgt. (Frequency characteristics: 45 to 1 kHz, True RMS)
Power [Single phase] 0.005 kW to 360.0 kW
Basic accuracy: ±2.0% rdg. ±7 dgt. (50/ 60 Hz, Power factor=1)
[Balanced three-phase 3-wire] 0.020 kW to 623.5 kW
Basic accuracy: ±3.0% rdg. ±10 dgt. (50/ 60 Hz, Power factor=1)
[Balanced three-phase 4-wire] 0.040 kW to 1080 kW
Basic accuracy: ±2.0% rdg. ±3 dgt. (50/ 60 Hz, Power factor=1)
Harmonic levels (CM3286-01only *2) Voltage/ current harmonic levels up to 30th, Content factor,
Total harmonic distortion ratio
Other functions [Phase angle *1] lead -180.0° to lag 179.9°, [Power factor]
-1.000 to 1.000 [Frequency] 45.0 Hz to 999.9 Hz, PEAK, Phase
detection, Max / Min / Avg value display, Auto hold, electric meter
comparison, unbalanced 3-phase power estimate display, etc.
Dustproof and waterproof IP54 (EN60529) Grip, excluding lever
Risk of electric shock from measured conductors increases when wet
Interface Bluetooth® 4.0LE
Power supply LR03 Alkaline battery ×2
Core jaw dia. φ 46 mm (1.81 in)
Dimensions and mass 82 mm (3.23in) W × 241 mm (9.49in) H × 37 mm (1.46in) D, 450 g (15.9 oz)
Accessories Connection cord L9257 ×1, LR03 Alkaline battery ×2, Carrying case C0203 ×1, Instruction manual ×1
[CM3286-01 only]Notice Regarding Equipment That Emits Radio Waves ×1

Countries and regions where wireless operation is currently supported (CM3286-01)Last up date: May 26, 2017

Wireless certification Japan, United States, Canada, Austria, Belgium, Bosnia and Herzegovina, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Liechtenstein, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey, United Kingdom, and Chile
Exempt from the wireless regulations Viet Nam, Hong Kong, Macao, India, Russian Federation, Colombia, Pakistan, Vanuatu, and Peru

Catalogs

Quickly check current, voltage, power, and power factor: CM3286

Precisely identify electricity theft: CM3286

Manuals

AC CLAMP POWER METER CM3286,CM3286-01 [9MB]

Declaration of Conformity

AC CLAMP POWER METER CM3286,CM3286-01 [40KB]

Options

Adapter

 

CLAMP ON ADAPTER 9290-10

• Primary 1000A, secondary 100A (1/10 ratio) output • Superior phase angle characteristics for power

Bundled Accessories

 

CARRYING CASE C0203

Input cable (B)

*Voltage is limited to the specifications of the input modules in use.

 

GRABBER CLIP 9243

Attaches to the tip of the banana plug cable, Red/ Black: 1 each, 196 mm (7.72 in) length, CAT III 1000 V

Input cable (F)

* Voltage input via banana terminals limited by the voltage specifications of the respective input unit.

 

MAGNETIC ADAPTER SET L4937

Attaches to the tip of the banana plug cable, CAT III 1000V

BUS BAR CLIP SET L4936

Attaches to the tip of the banana plug cable, CAT III 600V

ALLIGATOR CLIP SET L4935

Attaches to the tip of the banana plug cable, CAT IV 600V, CAT III 1000V

EXTENSION CABLE SET L4931

Expands the length of the cable with banana plug, 1.5 m (4.92 ft) length

Input cable options

Test Pin Set L4932 is required when using the Small Alligator Clip Set L4934.

 

BREAKER PIN SET L4939

Attaches to the tip of the banana plug cable, CAT III 600V

TEST PIN SET L4938

Attaches to the tip of the banana plug cable, CAT III 600V

TEST PIN SET L4932

Attaches to the tip of the banana plug cable, CAT IV 600V, CAT III 1000V

Input/Output cords

*The 9615 is bundled

 

CONNECTION CORD L9257

1.2 m (3.94 ft) length

Software

*For the BT3554-01 only

 

GENNECT Cross (free app)

• Streamline tasks that require repeated measurement and recording of values • Link data and create reports to troubleshoot problems • Available for Android, iOS and Windows

Test leads A

Options for the L9207-10

 

TEST LEAD L9207-10

90 cm (2.95 ft) length

Test leads B

Options for the L4930, Test Pin Set L4932 is required when using the Small Alligator Clip Set L4934.

 

CONNECTION CABLE SET L4930

1.2 m (3.94 ft) length

Voltage measurement

*PW9020 ×4 pieces are bundled, additional single sensors also available

 

MAGNETIC ADAPTER 9804

Attaches to the tip of the L9438s or other voltage cord, red/black set

There are no drivers, firmware or software available for this product.

Translate »