Data Acquisition (DAQ) for Service, Maintenance, and Production Applications

  • 2ch Analog + 4ch Logic 1M-Sampling/s 12-bit A/D resolution

A Single Memory Recorder that can Observe Waveforms like an Oscilloscope and Record RMS Value Fluctuations

MEMORY HiCORDER MR8870

  • Max. 16ch Analog + 8ch Logic 60ch scanner 500k-Sampling/s 16-bit A/D resolution

1000V Direct Input, Portable 16-channel Memory Recorder for Data Acquisition During Vehicle Testing with Direct CAN Bus Input

MEMORY HiCORDER MR8875

  • Max. 4ch Analog + 8ch Logic 1M-Sampling/s 14-bit A/D resolution

Portable Memory Recorder for High Voltage Testing and Fully Isolated Data Acquisition Across 4 Channels

MEMORY HiCORDER MR8880

Data Acquisition PC Software

  • For Memory HiCorder (Exclusively for Apple Inc. iPad) Free download from the App Store

Analyze Memory HiCorder waveforms right on your iPad

iPad App for Memory HiCorder HMR Terminal

  • For LAN communication with the MR8740/8741, MR8847 series, 8826 For data collection and remote control

Networking Software Lets You Remotely Control Memory Recorders via a LAN Connection

LAN COMMUNICATOR 9333

  • Achieve functions identical to those of the Memory HiCorder 8860 Series on a PC

Windows Software Provide Advanced Analysis of Measurement Data Recorded by the Hioki 8860 Series Memory HiCorders

MEMORY HiVIEWER 9725

  • Convert data, print and display waveforms

Windows Software Provide Advanced Analysis of Measurement Data Recorded by Hioki Memory HiCorders

WAVE PROCESSOR 9335

Memory Recorder Options

  • 2ch, 10 mHz to 100kHz function generator Arbitrary waveform generator function
  • 2 MHz D/A refresh rate Max.15 V output

Pair with Memory Recorders to Achieve a Single-device Solution for Waveform Recording and Generation

ARBITRARY WAVEFORM GENERATOR UNIT U8793

  • Select CAN-Bus information and convert them into analog/logic signals 12ch analog output + 24bit logic output

Convert CAN Bus Signals Across 12 Channels and Further Analyze Using Recorders or Data Loggers

CAN ADAPTER 8910

  • For up to 2 kV DC or 1 kV AC Use with AC Adapter 9418-15 Frequency band width up to 10MHz

High Performance Differential Probe Supports 3 Types of Measurements

DIFFERENTIAL PROBE 9322

  • Waveform only for exclusive use with Memory HiCorders (P9000-01) or waveform/RMS value switchable (P9000-02) For use with input of up to 1 kV AC/DC Requires separate power supply

Easily Connect to Hioki Memory HiCorders and HiLoggers for High Voltage Testing

DIFFERENTIAL PROBE P9000

  • 4 channels for contact voltage signals 500ns response Miniature terminal type

Detect the Presence of Voltage or Relay Contact Signals with Memory HiCorders

LOGIC PROBE 9320-01,9320

  • 4 channels for contact voltage signals High-speed 100ns response

Detect the Presence of Voltage or Relay Contact Signals with Memory HiCorders at High-speeds

LOGIC PROBE 9327

  • 4 isolated channels ON/OFF detection of AC/DC voltage Large terminal type

Detect AC/DC voltage with Memory HiCorders

LOGIC PROBE MR9321,MR9321-01

  • Supports φ1mm to 2.5mm covered wires 10Hz to 100kHz frequency bandwidth 5Vrms 14Vp-p rated measurement voltage

Capture Voltage Signals from Outside the Wire Cover

NON-CONTACT AC VOLTAGE PROBE SP3000-01

  • 8 ch Pulse output 0.1 Hz to 20 kHz Pattern output

Pulse Generator Input Module for Control Simulation Testing

PULSE GENERATOR UNIT MR8791

  • 4 ch DC output ± 10 V Sinewave output 10 mHz to 20 kHz

Waveform Generator Input Module for Control Simulation Testing

WAVEFORM GENERATOR UNIT MR8790

Pen Recorders

  • 150 mm (5.91 in) chart width, compact size 1 pen: PR8111 2 pens: PR8112 Power with AC adapter or dry cell batteries

1- or 2-Pen Chart Recording of DC Voltage Signals with an Easy-to-Use Portable Pen Recorder

PEN RECORDER PR8111, PR8112

Data Acquisition (DAQ) for R&D and Testing Applications

  • 8860: Max. 16ch Analog + 16ch Logic, or 64ch Scanner Unit 8861: Max. 32ch Analog + 16ch Logic, or 128ch Scanner Unit 20M-Sampling/s

High-speed 16- or 32-channel Memory Recorders Offer Data Acquisition, Oscilloscope and Data Logger Functionality to Record Waveforms in Any Situation

MEMORY HiCORDER 8860, 8861 Exclusive Academic Offer

  • Max. 54ch/16ch Analog + 16ch Logic 20M-Sampling/s 12-bit/16-bit A/D resolution

High-speed, 54- or 16-channel Memory Recorders Provide Advanced Data Acquisition and Rack-Mount Systems Integration

MEMORY HiCORDER MR8740, MR8741

  • Max. 32ch Analog + 32ch Logic
  • Max. 28ch Analog + 64ch Logic
  • 20M-Sampling/s
  • 16M to 128M-Word Memory (4ch)
  • 12-bit/16-bit/24-bit A/D resolution
  • USB, SSD, CF-card

High-speed 20MS/s 32-channel Fully-isolated Memory Recorder Provides Simultaneous Data Acquisition Over 32 Analog + 32 Logic Channels

MEMORY HiCORDER MR8827 Exclusive Academic Offer

  •  Max. 16ch Analog + 16ch Logic
  • Max. 10ch Analog + 64ch Logic
  • 20M-Sampling/s
  • 32M to 256M-Word Memory (2ch)
  • Waveform judgment function
  • 12-bit/16-bit A/D resolution
  • USB, HD, CF-card

High-speed 20MS/s, 16-channel, Fully Isolated Memory Recorder for On-site Jobs and R&D

MEMORY HiCORDER MR8847A Exclusive Academic Offer

  • Max. 16ch Analog + 8ch Logic 60ch scanner 500k-Sampling/s 16-bit A/D resolution

1000V Direct Input, Portable 16-channel Memory Recorder for Data Acquisition During Vehicle Testing with Direct CAN Bus Input

MEMORY HiCORDER MR8875